Your Antunes Steamer is designed to operate smoothly and efficiently if properly maintained.  

However, the following is a list of checks or activities to make in the event of a problem:  

Problem

Possible Cause

Who 

Services 

Steamer

Corrective Action

Excessive steam 

escaping from the 

cavity

Cavity Drain Screen is 

Plugged

User

Remove both drawers of steamer and clean Drain Screens.

Drain Hose is kinked or 

2" air gap is blocked

User

Make sure the drain hose are not kinked and a 2” air gap is 

maintained to the floor drain or drain box.

Excessive water is 

pouring out of the cavity 

Water Probes Scaled

User

Run one or more clean cycles. Check the water treatment 

system.

Cavity Drain Screen is 

Plugged

User

Remove both drawers of steamer and clean Drain Screens.

Drain Hose is kinked or 

2" air gap is blocked

User

Make sure the drain hose are not kinked and a 2” air gap is 

maintained to the floor drain or drain box.

Water fill Solenoids are 

clogged

Auth Service 

Rep Only

Check water fill solenoids for debris.

Steam Solenoid Valves 

are clogged.

Auth Service 

Rep Only

Check Steam Solenoids Valves for debris and continuity (N.C.) 

for normal operation.

Steamer Does Not Heat

Steamer is unplugged 

or circuit breaker is 

tripped

User

Make sure steamer is plugged in and circuit breaker has not 

tripped.

Cavity Drawer(s) are 

not fully inserted.

User

Make sure both cavity drawers are pushed in all the way.

Loose component 

connections

Auth Service 

Rep Only

Check operation of Pressure Switch, Control Board, Contactor, 

and Cartridge Heaters for continuity and/or loose connections.

Steamer fails to reach 

proper temperature

GUI Settings have 

changed

User

Adjust GUI Control Settings and set Boiler Temperature (BT) 

to 268 deg 

0

F. See settings/ operation section in this manual 

on page 17.

Voltage issue on 

electrical components

Auth Service 

Rep Only

Check for voltage or open circuit on control board, contactor, 

heaters, pressure switch, or GUI control Panel.

Steamer is continually 

draining and doesn’t 

build pressure or 

temperature

System buildup or 

blockage.

User

Turn steamer off and run a clean cycle.  Allow steamer 

to complete the entire clean cycle – See preventative 

maintenance section of this manual on page 18.

Drain Valve 

malfunction/failure.

Auth Service 

Rep Only

Clean the drain valve seat or replace drain valve with the 

steamer powered down.  Once powered up, run a clean cycle 

to ensure trouble free operation. 

Steam is escaping from 

the rear panel of the 

steamer

Internal Component 

Failure

Auth Service 

Rep Only

Shut down and unplug the unit. Call Authorized Service Rep.

Water is escaping from 

rear of steamer during 

initial operation

Water Inlet Hose has 

connection problem

User

Check inlet water feed hose to steamer. Reconnect if needed 

and/or replace.

Water level probe 

scaled up

User

Run a cleaning cycle.

System Error Displayed 

on GUI

System Error - Refer 

to Error Messages on 

Next Page

User

Turn steamer OFF and then back ON. If error persists, contact 

Authorized Service Rep

Содержание IS-8000

Страница 1: ... Steam and Hold Mfg Number 9100948 Owner s Manual Infini Steam IS 8000 www antunes com CAUTION Read all instructions before using the unit Original Instructions P N 1011582 Rev F 07 21 ...

Страница 2: ...tion and have it ready when calling for assis tance The serial number is on the specifi cation sticker located on the system Equipment Information to Save Purchased from Date of purchase Model number Serial number Manufacturing number Authorized Service Agency Name Phone No Address Table of Contents Overview 2 Before Use 2 In Case of Damage 2 Website 2 Service Technical Assistance 2 In Case of Dam...

Страница 3: ...d the unit free and clear of all combustible materials Failure to do so may result in fire or property damage y Opening steamer drawers during operation releases steam Compartment and contents may be hot Maintenance y Do not use abrasive materials they can damage the unit s stainless steel finish y Do not use corrosive chemicals in this equipment y Chlorides or phosphates in cleaning agents e g bl...

Страница 4: ...rdness Calcium Magnesium 1 GPG Maximum Total Alkalinity 600 PPM Maximum Total Silica 150 PPM Maximum Iron Content 0 1 PPM Maximum pH 6 5 10 5 Total Dissolved Solids 2 500 PPM Maximum Oxygen Content 0 PPM Carbon Dioxide 0 PPM Water Pressure Requirements Minimum Water Pressure 40 psig Maximum Water Pressure 60 psig 33 00 26 40 26 70 IMPORTANT Failure to follow these water quality conditions will voi...

Страница 5: ... steamer 1 Remove steamer and all accessories from the packaging 2 Remove all packing materials and protective coverings from the steamer 3 Record the model number serial number and installation date of your steamer and keep this information for future reference Space for this is provided on page 2 NOTE If any parts are missing or damaged contact Antunes IMMEDIATELY at 1 800 253 2991 toll free in ...

Страница 6: ...ent clean cycles It is recommended that the water quality conditions in this documents be met An Antunes Water Treatment System is recommended to best attain these water conditions Consult Antunes Customer Service for more information on and Antunes product that is designed for the Steam and Hold NOTE Failure to follow these water quality conditions will VOID the warranty and may cause the steamer...

Страница 7: ... cutout on either side The cutout is located right behind the roller On the bottom rear edge of each drawer is a tab extension The tab helps to keep the drawer inside the cavity See Figure 5 Rail Cutout To Install 1 Hold the drawer at about a 30 degree angle Insert the drawer tabs through the cutouts in the drawer rails so the tabs are under the rails Tab Extension 2 Rotate the drawer down and ins...

Страница 8: ...colors and timers y Yellow The drawer is STEAMING y Green The drawer is HOLDING y Red The drawer is EXPIRED System Is Ready Settings Start All Chicken No Product No Product No Product No Product Tamale 165F 0F 0F 0F 165F 0 0 2 7 Turkey 165F 0 3 5 9 0 0 5 9 0F 0F No Product 10 Once a drawer has finished steaming the drawer will switch to holding Product may be removed and used during any time while...

Страница 9: ...o change the time and date on the Steamer 1 Select Edit Clock in the Tools Screen 2 The screen will display as shown below Edit Clock Exit Set 01 01 01 01 MM DD HH MM YY Period 01 01 00 00 AM 00 00 00 AM 3 Tap each designated field to set the time and date Press Set to save changes The clock will begin ticking Edit Clock Exit Set 05 14 20 05 MM DD HH MM YY Period 14 20 12 21 PM 12 22 25 PM Edit Wa...

Страница 10: ...5 Press Done to return to the Service Menu Maintenance Daily The Steam and Hold requires a minimal amount of maintenance Daily maintenance helps keep the steamer running smoothly and free of any excess buildup that comes from daily use and wear These steps should be completed at the end of every day to ensure that the steamer maintains optimum efficiency Open the drawers and remove the steam pans ...

Страница 11: ...e and remove from steamer 4 Remove top of Cleaning Cartridge by pulling top off the plastic housing 5 Pour 4oz of cleaning solution into the plastic housing Figure 10 NOTE Use two 2oz Delimer Packets in Cleaning Cartridge per Clean Cycle Figure 9 Clean Cycle Rotate the door down and remove key from pocket Insert key into clean cycle cartridge counter clockwise and remove from steamer Remove top of...

Страница 12: ...ycle Scaled Clean WARNING Failure to properly follow the cleaning instructions for the unit will result in excess buildup of scale and lime as seen in the examples below Excess buildup of scale and lime may cause damage to the unit and will void the warranty ...

Страница 13: ...t and will void all warranties Error Description FRAM Missing Control Board Failure Zero Cross TC0 Open Thermocouple Broken or Disconnected TC1 Open FlipFlop ON Power Switch Circuit Malfunction FlipFlop OFF Bootload Fail Software Update via USB Stick Failed OPTION Write Failed EEPROM Failure MENU Write Failed PID Write Failer 24V Missing 24VDC Power Supply Failed Display Missing Touch Screen Displ...

Страница 14: ...wers are pushed in all the way Loose component connections Auth Service Rep Only Check operation of Pressure Switch Control Board Contactor and Cartridge Heaters for continuity and or loose connections Steamer fails to reach proper temperature GUI Settings have changed User Adjust GUI Control Settings and set Boiler Temperature BT to 268 deg 0F See settings operation section in this manual on page...

Страница 15: ... 24 Volt Power Supply MSP 200 24 SSR1 SSR2 SSR1 SSR2 Water Level Board SSR1 SSR2 SSR1 SSR2 Wires go to the SSRs SSR input wires connected to J8 J8 on main board MOV Board Snubber o o Buzzer Board J11 Buzzer Cavity BreakoutBoard Wiring This is Repeated for all 8 Drawers 1 3 2 4 Drawer Reed Switch Drawer Thermister Drawer Solenoid CAT 5 Cable Power Push Button Board J101 J108 Wiring Touch Screen Dis...

Страница 16: ...F 07 21 16 72 4 17 66 71 60 23 95 94 61 75 6 79 201 219 196 69 15 49 188 Item 15 119 125 111 121 224 226 222 166 223 228 224 225 227 Exploded Diagram 1 Mfg No 9100949 ONLY 135 137 62 185 48 32 33 28 28 23 18 136 Item 4 ...

Страница 17: ...582 Rev F 07 21 17 Exploded Diagram 2 124 57 182 189 191 5 190 56 206 186 7 116 171 77 16 31 77 46 174 208 58 30 186 174 199 157 105 129 128 106 92 104 Item 7 211 214 209 217 212 209 210 214 213 78 215 Item 208 ...

Страница 18: ... P N 1011582 Rev F 07 21 18 Exploded Diagram 3 70 167 192 218 55 198 197 194 166 187 53 207 11 157 174 59 74 174 ...

Страница 19: ... P N 1011582 Rev F 07 21 19 Exploded Diagram 4 1 127 129 70 102 126 14 9 3 102 133 114 113 122 2 206 182 54 190 58 187 39 188 201 138 195 113 31 46 116 57 16 208 219 ...

Страница 20: ...View Heat sync Pressure Release Switch Water Level Board Power Supply Board Circuit Breaker Contactor Cavity Breakout Board Drain Tubing Photo Diagram Main Control Board Display Board Boiler SSR Relay Power Button Board Solenoid System Drain Power Cord Treated Water Intake Regulator Assembly ...

Страница 21: ... No Part Description Qty 59 0510972 Side Pane Rh 1 60 0510973 Cubby Front Brace 1 61 0510978 Control Panel 1 62 0510979 Front Plate 8 66 7002357 Drip Pan Kit 1 69 0511265 Clean Cycle Mt Brkt 1 70 0511272 Electrical Mount Bracket 1 71 0511278 Front Cover Panel 1 72 0511284 Front Cover Panel Os 1 74 0511289 Side Ele Panel 1 75 0511290 Front Access Cover 1 76 0511357 Bracket Clean Cycle Support 2 77 ...

Страница 22: ...8 4 180 3100308 Weld Nut 10 32 8 181 3250302 1 4 20 Pem Nut Sst 32 182 4000216 Fan 1 183 4010254 Micro Switch 2 184 4010260 Switch Reed 8 185 4010261 Actuator Reed Switch 16 186 4040207 Solenoid Valve 060 High Temp 8 187 4040239 Solenoid Valve 088 Orifice 2 188 4040266 Low Pressure Switch Fixed 28 Psi 1 Item No Part Description Qty 189 4050180 Heat Sink 2 190 4050236 Contactor 2 Pole Normally Open...

Страница 23: ... P N 1011582 Rev F 07 21 23 Notes ...

Страница 24: ...n any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment do not constitute a warranty charge 3 If shipment is damaged in transit the purchaser should make a claim directly upon the carrier Careful inspection should be made of the shipment as soon as it arrives and visible damage should be noted upon ...

Отзывы: