9
P/N 1011190 Rev. G 01/17
Problem
Possible Cause
Corrective Action
Control Display flashes FPLt
continuously. Buns not toasting
properly.
Front Platen temperature is below 515
°
F (268
°
C).
Allow the unit to warm up for 30 minutes and then recheck. If the
Control Display still flashes FPLt, contact your maintenance person
or Authorized Service Agency for service.
Failed front Platen Thermocouple.
Contact your maintenance person or Authorized Service Agency
for service.
Failed Control Board
Control Display flashes rPLt
continuously. Buns not toasting
properly.
Rear Platen temperature is below 535
°
F (279
°
C).
Allow the unit to warm up for 30 minutes and then recheck. If the
Control Display still reads rPLt, contact your maintenance person
or Authorized Service Agency for service.
Failed Rear Platen Thermocouple.
Contact your maintenance person or Authorized Service Agency
for service.
Failed Control Board.
Control Display flashes Er 9
continuously.
Control Compartment ambient temperature is
above 150
°
F (66
°
C)
Verify side vents on toaster are unblocked and not near other
heating appliances. If problem persists, contact your maintenance
person or Authorized Service Agency for service.
Failed Cooling Fan.
Failed Control Board
Control Display Flashes FSSr
continuously. Buns Burn.
Failed Front Platen Solid State Relay.
Contact your maintenance person or Authorized Service Agency
for service.
Failed Control Board.
Failed Front Platen Thermocouple.
Control Display flashes rSSr
continuously. Buns Burn.
Failed Rear Platen Solid State Relay.
Contact your maintenance person or Authorized Service Agency
for service.
Failed Control Board.
Failed Rear Platen Thermocouple.
Control Display flashes Er 13
continuously. Buns not toasting
properly.
Loose Front Platen Thermocouple connection
on Control Board or the Front Platen Thermo-
couple is open.
Re-secure the Front Platen Thermocouple to the Control Board. If
the Control Display still reads Er 13, check the front Thermocouple
for continuity. Contact your maintenance person or Authorized
Service Agency for service.
Failed Control Board.
Control Display flashes Er 11
continuously. Buns not toasting
properly.
Loose Rear Platen Thermocouple connection on
Control Board or the Rear Platen thermocouple
is open.
Re-secure the Rear Platen Thermocouple connection to the Control
Board. If the Control Display still reads Er 11, check the Rear
Thermocouple for continuity. Contact your maintenance person or
Authorized Service Agency for service.
Failed Control Board.
Control Display flashes Er 12
continuously. Buns not toasting
properly.
Shorted Front Platen Thermocouple to ground.
Disconnect and re-secure the Rear Platen Thermocouple connec-
tion to the Control Board. If the Control Display still reads Er 12,
check the Rear Thermocouple for continuity. Contact your mainte-
nance person or Authorized Service Agency for service.
Failed Control Board
Control Display Flashes Er 10
continuously. Buns not toasting.
Shorted Rear Platen Thermocouple to ground.
Re-secure the Rear Platen Thermocouple connection to the Control
Board. If the Control Display still reads Er 10, check the Rear
Thermocouple for continuity. Contact your maintenance person or
Authorized Service Agency for service.
Failed Control Board.
Control Display flashes StoP.
Mechanical bind in one or both conveyors.
Enter “user mode” to check the motor speed. Check both convey-
ors for mechanical binds. Test the motor. Replace necessary parts.
Contact your maintenance person or Authorized Service Agency
for service.
Worn or damaged Ball Bearings.
Drive chain or sprockets damaged.
Failed Motor.
Failed Control Board.
Control Display flashes SpEd.
Mechanical bind in one or both conveyors.
Enter “user mode” to check motor speed. Check both conveyors for
mechanical binds. Replace necessary parts. Contact your mainte-
nance person or Authorized Service Agency for service.
Worn or damaged Ball Bearings.
Conveyor chains loose or damaged.
Drive chain or sprockets damaged.
Crowns and/or Heels must be
forced into the toaster. Buns
sticking and burning.
Silicone Belts not cleaned properly.
Clean Silicone Belts as described in the Maintenance section of this
manual.
Silicone Belts are not tack/sticky to the touch
(replace every 2-4 months).
Clean Silicone belts. If the Silicone Belts are too worn, replace them
as described in the Maintenance section of this manual.
Silicone Belts are dirty, worn, or damaged (re-
place every 2-4 months).
Clean or replace Silicone Belts as described in the Maintenance
section of this manual.
Buns do not meet specifications.
Contact your bun supplier.