9
- A 4.0 m long flue piping and rain cap are included in the delivery. In most cases this is enough
for vertical pipe installations.
- Often the flue pipe must also be led horizontally through the heater room wall and the parts of
the vertical pipe are installed in vertical position outside the heater room. In this case,
additional flue pipe elbows and parts of straight pipe are needed for installation. Note the
condensation of sulphur in a clay pipe. It is advisable to install the first part of the flue pipe in
a vertical position so that the condensed liquid will not flow back into the heater. From this
point on the flue pipe can be directed straight upwards.
- Pay special attention to sufficient supporting and staying of the pipe. At maximum 4.0 m tall
vertical pipes are allowed to be supported only by the heater. The longer pipes and elbows
require a separate supporting structure. A vertical pipe must also be supported sideways
either with stay wires or supporting bars.
- If the heater is installed outdoors, the burner must be covered completely against rain and
snow. The electric motor and oil burner are not covered against rain.
3. Oil Burner and Pipes
The installation and adjustment of the oil burner and the installation of the oil pipes must be left
to an authorised oil burner mechanic.
Instructions for the oil burner mechanic:
- Use exclusively 2-pipe system with 10/12 mm copper pipes.
- Always check the size of the nozzles before putting the heater into service.
Please refer to the lower part of the table on the last page for recommended oil flow for the
heaters. The values in the table for the heater air adjustment are only indicative. Assign a
specialized mechanic for more accurate adjustment.
Nozzles:
- Danfoss 80°, spray pattern S or B
- Monarch 80°, spray pattern R or PLP
If you want maximum output from the heater, see the oil pressure table (on the last page of this
manual) to find out how the oil pressure affects the amount of burning oil when different nozzles, and
pairs of nozzles, are used
NOTE!
Do not install over-sized nozzles or adjust the oil pressure setting so high
that the maximum permissible oil amount for the burner will be exceeded