Chapter 4: DESCRIPTION OF CONNECTION
Page 20 of 30
Operating Manual FU3AM-03
4.7 Digital 10-bit set value parallel input X5
9
1
X5
X5-1 GND
Reference potential for
digital set value inputs
X5-2 SW_2
digital set point, Bit 2
X5-3 SW_3
digital set point, Bit 3
X5-4 SW_4
digital set point, Bit 4
X5-5 SW_5
digital set point, Bit 5
X5-6 SW_6
digital set point, Bit 6
X5-7 SW_7
digital set point, Bit 7
X5-8 SW_8
digital set point, Bit 8
X5-9 SW_9
digital set point, Bit 9
Note: For compatibility reasons the inputs SW_0 and SW_1 are to be found on X4-12
and X4-11. If only 8-bits are to be used, SW_0 and SW_1 must be on Low (and/or open).
Low = 0 ... +2VDC or open
High = +15 ... 30 VDC
Cable cross section: 0.4 … 1.5 mm² (AWG 21 … 16) single/fine strand
8mm
4.8 Bridge connector for one-fault safety
Bridge connector for wiring of the one-fault safety