12
If Channel A has a value from 0 to 5, the unit is OFF.
Between the values 6 to 249 the volume of fog output is regulated.
With 6 being the minimum volume
of fog produced and 249 approaching the maximum. The volume output rises as the DMX value is
increased.
If Channel A has a value from 250 TO 255, the machine will operate at maximum output.
Note:
In the example above, if the machine were assigned the DMX address of 124, Channel A would
correspond to DMX address 124.
In general, Antari fog machines with onboard DMX conform to the following performance specifications:
1. Average Operating temperature = 250ºC
2. Fogger can maintain maximum output for 30 seconds or more
3. Fogger can maintain constant output at 25% volume setting (roughly a value of 75).
20B
Addressing (Z-1200II)
Each device occupies 1 channel. To ensure that the control signals are properly directed to each device, they
require adressing. This is to be adjusted for every single device by changing the DIP-switches as set out in the
table below.
The starting address is defined as the first channel from which the device will respond to the controller.
Please make sure that you do not have any overlapping channels in order to control each device correctly and
independently from any other fixture on the DMX data link. If two, three or more devices are addressed similarly,
they will work similarly.
Occupation of the DIP-switches: