background image

Antaira Technologies - Industrial Ethernet Switches 

LNP-0800G-M12-67-24 User Manual V1.0 

 

 

 

 

 

 

LNP-0800G-M12-67-24

 

8-Port Industrial M12 IP67 Waterproof Gigabit PoE+ Ethernet Switch, 

w/8*10/100/1000Tx (30W/Port) M12 Connector (X-Coded), 24~55VDC; 

-10° to 60°C 

 

 

Version 1.0 

(September 2018)

 

User Manual 

 

 

 

Содержание LNP-0800G-M12-67-24

Страница 1: ... Switches LNP 0800G M12 67 24 User Manual V1 0 i LNP 0800G M12 67 24 8 Port Industrial M12 IP67 Waterproof Gigabit PoE Ethernet Switch w 8 10 100 1000Tx 30W Port M12 Connector X Coded 24 55VDC 10 to 60 C Version 1 0 September 2018 User Manual ...

Страница 2: ...arks or registered trademarks of their respective owners Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Antaira Technologies LLC may make improvements and or changes to the product and or specifications of the product described in t...

Страница 3: ...etermined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV te...

Страница 4: ...ront Panel 4 2 3 Top View 4 2 4 LED Indicators 5 2 5 Grounding 6 2 6 Ethernet Ports 6 2 7 Power Inputs 7 2 8 Relay Contact and Digital Input 8 2 9 Prioritization of PoE Ports 10 2 10 Bypass Function 10 2 11 Prioritization of Packets 11 3 Mounting Installation 12 3 1 Wall Mounting 12 4 Hardware Installation 14 4 1 Installation Steps 14 4 2 Maintenance and Service 15 5 Network Application 16 6 Troub...

Страница 5: ...hitecture 8K MAC Address Table Supports 12 2Kbytes Jumbo Frame 448Kbits memory buffer Power Input Redundant power DC 24 55V through M12 4 Pin T Coded male connector Max current 8 8A Max PoE output 200Watts Relay Contact 24VDC 1A resistive through M12 5 Pin A Coded female connector Operating Temperature Standard operating temperature model 10 C 60 C Case Installation Aluminum case IP67 protection I...

Страница 6: ...Antaira Technologies Industrial Ethernet Switches LNP 0800G M12 67 24 User Manual V1 0 2 with the device Shown in Figure 1 Figure 1 Caution Label ...

Страница 7: ...net Switches LNP 0800G M12 67 24 User Manual V1 0 3 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira Technologies LNP 0800G M12 67 24 W x H x D is 253 6mm x 122mm x 116 1mm Figure 2 1 ...

Страница 8: ... Holes for Wall Mounting 8 Grounding Screw 9 Power Input Port M12 4 Pin T Coded Male Connector 10 Product Label 11 10 100 1000Base T X Ethernet Port From Port G1 to G8 with M12 8 Pin X Coded Female Connector 2 3 Top View Figure 2 3 below shows the bottom panel of the LNP 0800G M12 67 24 that is equipped with 8 x M12 X Coded female connectors 1 x M12 T Coded male connector for dual DC power inputs ...

Страница 9: ...ssible conditions that would make the LED light up 1 If the current PoE outputs of all connected PDs were overloaded 200 Watts 2 If Power 1 or Power 2 was inactive 3 If the current PoE output of one or more PDs was overloaded 30Watts Off Since the last reset of the fault LED the PoE output of all connected PDs has not over 200W and no PD has been overloaded in this period and the power 1 power 2 h...

Страница 10: ...1 Power 2 and L A is for Link Activity 2 5 Grounding Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices The grounding screw symbol is shown blow in Figure 2 4 Figure 2 4 Caution Using a shielded cable achieves better electromagnetic compatibility 2 6 ...

Страница 11: ...ires that make up each wire pair Connection of Cables Use the twisted pair cable category 5e or the above cabling for M12 port connections The cable between the Ethernet switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long Minimum Wire Gauge 24AWG Maximum Transmission Length 100m 328ft Caution 1 Please use with copper conductors only 2 Use conductors with...

Страница 12: ...tion The power input specification is complied with the requirements of SELV Safety Extra Low Voltage and the power supply should be complied with UL 61010 1 UL 61010 2 201 2 8 Relay Contact and Digital Input The Ethernet switch is equipped with an M12 5 Pin A Coded female connector with a normally closed relay contact for fault alarm and a digital input DI for resetting relay and rebooting unit T...

Страница 13: ...relay contact circuit is opened and the FAULT LED lights up In addition even after the abnormal situation has been removed the relay contact is still open and FAULT LED remains active unless using the digital input to reset that See the next section for information on Digital Input Note If only using one power source jumper Pin 1 to Pin 4 and Pin 2 to Pin 3 on the M12 4 Pin T Coded power cable to ...

Страница 14: ...y and port G8 uses the lowest to determine which ports will provide the connected powered device PD power Each of the eight Ethernet ports of this switch can provide up to 30W and the maximum total PoE output is 200Watts If the switch can provide power for all connected PD it doesn t use the prioritization rule to allocate power Only if the current PoE provisioning on all connected PD oversubscrib...

Страница 15: ...est priority packet is transmitted first by the switch Quality of Service QoS is used to ensure the priority of network traffic receiving correct treatments so it eliminates the unpredictability issue of network traffic A priority queue is a data type which identifies an item with the highest priority in a system To map each CoS value to a QoS priority queue is to prioritize the type of traffic at...

Страница 16: ...ch to a wall Note Recommended use the M6 screws 2 Based on the Figure 3 2 on the following page which shows the positions of 4 screw holes on the left and right side of the switch make 4 screw holes on a wall accordingly 3 Insert the screws through the screw holes on the switch and screw the switch into the wall Shown above in Figure 3 1 4 To remove the switch from the wall do the opposite from th...

Страница 17: ...Antaira Technologies Industrial Ethernet Switches LNP 0800G M12 67 24 User Manual V1 0 13 Caution Wall means industrial control panel wall Figure 3 2 ...

Страница 18: ...Ethernet switch from the original packing box 2 To hang the industrial Ethernet switch on a wall or DIN Rail please refer to the Mounting Installation section 3 Power on the industrial Ethernet switch then the power LED light will turn on a If you need help on how to wire power please refer to the Wiring the Power Inputs section b Please refer to the LED Indicators section for LED light indication...

Страница 19: ...power lines should be properly insulated as well as other cables Be careful when handling them so as to not trip over Do not under any circumstance insert foreign objects of any kind into the heat dissipation holes located in the different faces of the device This may not only harm the internal layout but might cause harm to user as well Do not under any circumstance open the device for any reason...

Страница 20: ...Ethernet Switches LNP 0800G M12 67 24 User Manual V1 0 16 5 Network Application This segment provides an example of an industrial M12 Ethernet switch application Figure 5 1 Figure 5 1 Industrial M12 Ethernet Switch Application Example ...

Страница 21: ...ily monitored with the LED indicators which help to identity if any problems exist a Please refer to the LED Indicators section for LED light indication 4 If the power indicator LED does not turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose power connections power losses or surges at the power outlet a Please contact Antaira for technical sup...

Страница 22: ... MDI MDI X connection DI 1 Digital Input DI State 0 30 8VDC State 1 10 30VDC Max input current 8mA Bypass Protection Ethernet Port 7 and Port 8 LED Indicators Power 1 Power 2 Fault PoE Load Ethernet Ports On link Flash data transmitting PoE On connected to PD devices Mechanical Characteristics Housing Plastic IP67 protection Dimension 37 13 x 215 73 x 32 8 mm W x H x D Weight Unit Weight 7 05 lbs ...

Страница 23: ...8 2 32 Free Fall 27 Shock 6 Vibration Green RoHS Compliant Safety FCC CE UL 61010 1 Pending UL 61010 2 201 Pending Warranty 5 Years Table 7 1 Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira www antaira com support antaira com www antaira eu info antaira eu www an...

Отзывы: