2.5 Reset Button
There is a Reset button located on the front panel of the industrial Ethernet switch that helps
users to reboot, restore default, or save running configurations by pressing the button for different
seconds. Please refer to
Table 2.2
for the timing and function.
Seconds
Function
1
Save running configuration to USB
4-6
Reboot the switch
7 or more
Restore factory default
Table 2.2 – Reset Button Functions
2.6 Ethernet Ports
RJ-45 Ports
RJ-45 Ports (Auto MDI/MDIX)
: The RJ-45 ports are auto-sensing for 10Base-T, 100Base-TX, or
1000Base-T connections. Auto MDI/MDIX means that the switch can connect to another switch or
workstation without changing the straight-through or crossover cabling. See the figures below for
straight-through and crossover cabling schematics.
RJ-45 Pin Assignments
Pin Number
Assignment
1
Rx+
2
Rx-
3
Tx+
6
Tx-
Table 2.3 - RJ45 Pin Assignments
Note:
The “+” and “-” signs represent the polarity of the wires that make up each wire pair.
All ports on this industrial Ethernet switch support automatic MDI/MDI-X operations. Users can
use straight-through cables (see figure below) for all network connections to PCs, servers, and
other switches or hubs. With straight-through cabling, pins 1, 2, 3, and 6 are at one end of the
cable and are connected straight through to pins 1, 2, 3 and 6 at the other end of the cable. The
table below (
Table 2.3
) shows the 10BASE-T/100BASE-TX/1000BASE-T MDI and MDI-X port pin
outs.
Pin MDI-X
Signal Name
MDI Signal Name
1
Receive Data plus (RD+)
Transmit Data plus (TD+)
2
Receive Data minus (RD-)
Transmit Data minus (TD-)
3
Transmit Data plus (TD+)
Receive Data plus (RD+)
6
Transmit Data minus (TD-)
Receive Data minus (RD-)
Table 2.4 - Ethernet Signal Pin