2.9 Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of the terminal block connector as the picture shows below in
Figure 2.8
. By inserting the wires, it will detect the fault status including power failure or port link
failure (managed industrial switch only) and form a normal open circuit. An example is shown below
in
Figure 2.8
.
Caution:
•
The wire gauge for the terminal block should range between 12 ~ 24 AWG.
•
If only using one power source, jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to
eliminate power fault alarm.
Attention:
•
Le calibre des fils du bornier doit être compris entre 12 et 24 AWG.
•
Si vous n'utilisez qu'une seule source d'alimentation, connectez les broches 1 à
5 et les broches 2 à 6 pour éliminer l'alarme de panne de courant.
Figure 2.8
Wiring the Fault Alarm Contact