Antaira Technologies - Industrial Ethernet Switches
LMP-0702G-SFP-24-V2 Series Hardware Manual V1.0
7
2.5 Reset Button
There is a ‘Reset’ button located on the front panel of the industrial Ethernet switch that helps
users to reboot, restore default, or save start-up configurations by pressing the button for
different seconds. Please refer to
Table 2.2
for the timing and function.
Seconds
Function
Fault LED
0s < t (press time) < 4s Reboot the switch
LED is flashing with green color
4s < t (press time) < 8s Restore factory default
LED is flashing with green and red color
8s < t (press time)
Backup configuration to USB
(startup-config)
LED is flashing with red color
Table 2.2
– Reset Button Functions
2.6 Ethernet Ports
•
RJ-45 Ports
RJ-45 Ports (Auto MDI/MDIX)
: The RJ-45 ports are auto-sensing for 10Base-T, 100Base-TX, or
1000Base-T connections. Auto MDI means that the switch can connect to another switch or
workstation without changing the straight-through or crossover cabling. See the figures below for
straight-through and crossover cabling schematics.
•
RJ-45 Pin Assignments
Pin Number
Assignment
1
Rx+
2
Rx-
3
Tx+
6
Tx-
Table 2.3 - RJ45 Pin Assignments
Note:
The
“+” and “-” signs represent the polarity of the wires that make up each wire pair.
All ports on this industrial Ethernet switch support automatic MDI operations. Users can use
straight-through cables (see figure below) for all network connections to PCs, servers, and other
switches or hubs. With straight-through cabling, pins 1, 2, 3, and 6 are at one end of the cable
and are connected straight through to pins 1, 2, 3 and 6 at the other end of the cable. The table
below (
Table 2.4
) shows the 10BASE-T/100BASE-TX/1000BASE-T MDI port pin outs.