background image

Antaira Industrial Ethernet Switches 

LMX-0500 Series User Manual V1.1 

 

54 

 

6.  Command Line Interface Management 

 

6.1 About CLI Management 

Besides WEB-based management, LMX-0500 series also supports CLI management. Users 

can use console or telnet to management switch by CLI. 

 

CLI Management by RS-232 Serial Console (115200, 8, none, 1, none) 

Before configuring by an RS-232 serial console, use an RJ45 to DB9-F cable to connect the 

switches’ RS-232 Console port to the PC’s COM port. 

 

Follow the steps below to access the console via RS-232 serial cable. 

 

Step 1: 

From the Windows desktop, click on Start -> Programs -> Accessories -> Communications -> 

Hyper Terminal.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All manuals and user guides at all-guides.com

Содержание LMP-0500 Series

Страница 1: ...Ethernet Switches LMP 0500 Series User Manual V1 1 i LMX 0500 Series 5 Port Industrial Managed Ethernet Switch with 5 10 100Tx 12 48VDC Power Input User Manual Version 1 1 All manuals and user guides...

Страница 2: ...ira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the copyright laws Disclaimer...

Страница 3: ...nterference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a cir...

Страница 4: ...D Indicators 5 2 5 Ethernet Ports 5 2 6 Cabling 7 2 7 Wiring the Power Inputs 7 2 8 Wiring the Fault Alarm Contact 8 3 Mounting Installation 9 3 1 DIN Rail Mounting 9 3 2 Wall Mounting 10 4 Hardware I...

Страница 5: ...atus 32 5 6 4 MSTI Configuration 33 5 7 802 1Q VLAN 35 5 7 1 802 1Q VLAN settings 35 5 7 2 802 1Q VLAN Settings 36 5 8 IGMP Snooping 36 5 8 1 IGMP Settings 37 5 8 2 IGMP Snooping Status Table 38 5 9 Q...

Страница 6: ...e 49 5 13 1 MAC Address Table 49 5 13 2 MAC Table Configuration 49 5 14 Maintenance 50 5 14 1 Upgrade 50 5 14 2 Reboot 51 5 14 3 Default 51 5 15 Configuration 51 5 15 1 Save 52 5 15 2 Backup Store 52...

Страница 7: ...erating temperature range models in STD 10 C to 70 C and EOT 40 C to 75 C and it also provided high EFT and ESD protection for any industrial networking application in factory automation ITS Power Uti...

Страница 8: ...rating temperature models 10 C to 70 C Extended operating temperature models 40 C to 75 C Case Installation IP 30 protection metal housing Installation in pollution degree to environment DIN Rail and...

Страница 9: ...Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMX 0500 series 5 Port industrial managed Ethernet switch with 5 10 100Tx 12 48VDC power input W x D x H is 46mm x 99mm...

Страница 10: ...switches is shown below in Figure 2 2 2 3 Top View Figure 2 3 below shows the top panel of the LMX 0500 series switch that is equipped with one 6 pin removal terminal block connector for dual DC powe...

Страница 11: ...ault Alarm Off System is in normal state Owner Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active Ring Green On Ring Network is active Off Ring Network is not active LAN P...

Страница 12: ...cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below Table 2 3 shows the 10BASE T 100BASE TX MDI and MDI X port pin outs The following figures show t...

Страница 13: ...00 meters 328 ft long 2 7 Wiring the Power Inputs Please follow below steps to insert the power wire 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the termina...

Страница 14: ...gure 2 8 By inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and forma normally open circuit An application example for t...

Страница 15: ...side of the industrial Ethernet switch 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN R...

Страница 16: ...on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch 4 Use the hook holes at the corners of the wall mounting...

Страница 17: ...he industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need he...

Страница 18: ...eatures that allow users to manage the switch from anywhere on the network through any Internet browser such as Internet Explorer version 9 0 or above is recommended Firefox Chrome and many others Pre...

Страница 19: ...he main status page of the Web Console will appear as below Figure 5 2 The online image of the switch will display the real time ports connection status 5 2 Basic Setting 5 2 1 System Information Belo...

Страница 20: ...is PoE Managed Switch System Location Factory Default blank Users can use this field to insert The physical location of this switch e g telephone closet 3rd floor The maximum allowed string length is...

Страница 21: ...red IP address is zero DHCP will retry If DHCP fails and the configured IP address is non zero DHCP will stop and the configured IP settings will be used The DHCP client will announce the configured S...

Страница 22: ...anges 5 2 4 System Time Terms Value Description Local Time Users can define the switch s local time or click Sync with browser button to have local time setup automatically Select Your Time Zone Users...

Страница 23: ...rt status 5 3 2 Port Configuration Users can assign or insert a value label for each port under each Port Name box enable or disable each port function state the speed duplex of each port and enable o...

Страница 24: ...ification Status Enable or disable a port Speed Duplex User can set the bandwidth of each port as Auto negotiation 100 full 100 half 10 full 10 half mode Flow Control Support symmetric and asymmetric...

Страница 25: ...order to provide users with the flexibility and compatibility when there are any existing switches that contains the standard ERPS protocol Ethernet Ring Protection Switching ERPS defined in ITU T G8...

Страница 26: ...hows the network redundancy ring status with the Ethernet Ring Protection Switch ERPS protocol 5 5 2 ERPS Configuration Below Figure 5 19 shows the ERPS configuration interface Figure 5 14 Redundant R...

Страница 27: ...node roles have the ability to block the port if the link attach to the port is failed and disconnected Ring ID ERPS ring ID ranges from 1 to 239 Ring ID distinguishes different Ring topology Channel...

Страница 28: ...rotocol is exclusive running within a switch Below are the steps to disable RSTP or MSTP Step 1 Login the switch with a web browser Step 2 Open the RSTP Configuration page under the Spanning Tree manu...

Страница 29: ...m ensures the traffic flows on all but the RPL ring link In order to achieve the loop avoidance mechanism ITU T G 8032 defines three roles in ERPS which are RPL Owner Node RPL Neighbor Node and Normal...

Страница 30: ...equired to be configured within the ERPS configuration Figure 5 20 RPL configured Architecture Caution Before enabling any ERPS protocols on any of the Ring Nodes please DO NOT connect all switches to...

Страница 31: ...s example Step 2 Choose a specific port from the dropdown box next to ring port 1 then set it as Normal from the dropdown box next to Role which locates below ring port 1 At this point Port 2 was chos...

Страница 32: ...number under Ring Port 0 and set it as the Normal node by clicking the dropdown box of Role then set another specific port number under Ring Port 1 as the Neighbor node as shown below in Figure 5 22...

Страница 33: ...switches Role of both Ring Port 0 and 1 as Normal Node as shown above in Figure 5 23 Please be sure no duplicate port number has been chosen within a managed switch s ERPS ring setting the incorrect c...

Страница 34: ...e blocking node However the user is still required to enable the RRPS protocol and assign a dedicated port number for each uplink port under Ring Port 0 and 1 but there is no requirement to setting th...

Страница 35: ...cascading effect away from the root bridge where each designated bridge proposes to its neighbors to determine if it can make a rapid transition Another extension of RSTP is the Multiple Spanning Tre...

Страница 36: ...Status Figure 5 26 shows the RSTP algorithm results 5 6 2 RSTP Configuration Users can enable disable the RSTP function and set the parameters for each port Figure 5 26 RSTP Information Interface Fig...

Страница 37: ...hout receiving STP configuration messages before attempting a reconfiguration Path Cost 0 200000000 Enter a value from 1 through 200000000 to define the path cost for the other switch from this transm...

Страница 38: ...y for a set of VLAN s instead of the whole network Different root switches and different STP parameters can be individually configured for each MSTI So one link can be active for one MSTI and the othe...

Страница 39: ...switch Revision User can insert the value from 0 65535 MTSI Instance Instance No VLAN Group There are 1 15 instance number user can insert which VLAN Group info into the belonging Instance number Pri...

Страница 40: ...from 1 through 200000000 to the other bridge from this transmitting bridge at the specified port Priority User can decide which port should be blocked by priority in LAN by select the value from 0 to...

Страница 41: ...is an IEEE 802 1Q specification standard and it is possible to create a VLAN across devices from different switch venders IEEE 802 1Q VLAN uses a technique to insert a tag into the Ethernet frames Tag...

Страница 42: ...hen IGMP snooping is enabled in a switch it analyzes all the IGMP packets between hosts connected to the switch and multicast routers in the network When a switch receives an IGMP report for a given m...

Страница 43: ...Value Description IGMP Protocol Check the box to enable or disable IGMP Snooping Querier Switch will be IGMP querier or not There should have the existing one and only one IGMP querier in an IGMP app...

Страница 44: ...and the only basic assurance that can be offered is the best effort traffic delivery To overcome this challenge Quality of Service QoS is applied throughout the network This ensures that network traf...

Страница 45: ...SCP only trusted DSCP Differentiated Services Code Point values are mapped to a specific QoS class and drop precedence level DPL Frames with untrusted DSCP values are treated as non IP frames CoS Clas...

Страница 46: ...er can assign each port a CoS value from 0 to 7 According to the IEEE 802 1p user can define each CoS value in 4 priority queues from Low to Normal Medium and High Click Apply button to save changes F...

Страница 47: ...nificant 6 bits of the ToS field are fully decoded into 64 possibilities and the singular code that results is compared against the corresponding bit in the IPv4 ToS priority control bit 0 63 Terms Va...

Страница 48: ...ng function by check the box Go To Interface User can use the dropdown box to choose the destination port as Port to mirror on feature Monitor Direction User can select the monitor direction from the...

Страница 49: ...olve network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP 5 11 1 SNMP Agent Terms Value...

Страница 50: ...MP Trap function by check the box Trap Destination IP User could insert the Server IP address as Trap Destination IP info Community User can release the SNMP to public for read only Click Apply button...

Страница 51: ...site network and device statuses 5 12 1 Syslog Setting The SYSLOG is a protocol to transmit event notification messages across networks Terms Value Description SYSLOG Mode Disable disable SYSLOG Local...

Страница 52: ...bottom corner of the interface Then the system event logs will display within the SYSLOG LIST window The SYSLOG LIST will contain up to 5 pages of system event log information Users also can click th...

Страница 53: ...ress Sender E mail Address Set up the email account to send the alert Mail Subject The subject of the mail Authentication Check the box to enable the Authentication function Username the authenticatio...

Страница 54: ...nt selection users can click the Apply button to save changes 5 12 5 Fault Alarm When any selected fault event has occurred the fault LED of the switch s front panel will light up and the electric rel...

Страница 55: ...arded through a given potential transmission port 5 13 1 MAC Address Table 5 13 2 MAC Table Configuration Users can check the checked box of each port and insert the port s VID and MAC address of the...

Страница 56: ...ra s website and store it within their local PC server or USB drive Terms Value Description FIRMWARE UPGRADE User can click the Choose File button to select the latest firmware from the local PC or Se...

Страница 57: ...n USB port Users can use the USB port feature to execute the Auto Load function to boot the switch s configuration that has been saved within the USB storage device or users can utilize this function...

Страница 58: ...IGURATION MANAGEMNET Backup Configuration By click the Backup button it allows user to backup the switch configuration setting to local PC or server Upload Configuration User can click the Choose File...

Страница 59: ...r filename does not exist system will return error If it succeeds system will reboot Ex file1 folder file2 5 15 3 Auto Load Backup Terms Value Description USB Auto Load Select USB Auto Load it can aut...

Страница 60: ...to management switch by CLI CLI Management by RS 232 Serial Console 115200 8 none 1 none Before configuring by an RS 232 serial console use an RJ45 to DB9 F cable to connect the switches RS 232 Consol...

Страница 61: ...Antaira Industrial Ethernet Switches LMX 0500 Series User Manual V1 1 55 Step 2 Input a name for the new connection Step 3 Select to use COM port number All manuals and user guides at all guides com...

Страница 62: ...property settings are as follows 115200 for Bits per second 8 for Data bits None for Parity 1 for Stop bits and none for Flow control Step 5 The Console login screen will appear Use the keyboard to en...

Страница 63: ...192 168 1 254 Subnet Mask 255 255 255 0 Default Gateway none User Name admin Password admin Follow the steps below to access the console via Telnet Step 1 Telnet to the IP address of the switch from t...

Страница 64: ...ure admin username admin configure admin password admin configure IP boot host dhcp configure ip address ip_addr ip_mask configure ip default gateway ip_router configure ip name server ip_addr_string...

Страница 65: ...o ntp sync weekly configure show ntp client enable configure show ntp client timeserver configure show clock timezone configure show ntp sync schedule enable configure show ntp sync minute configure s...

Страница 66: ...vlan group group_num group_portlist configure switchport pvid vlan_id interface switchport filter tagged untagged interface switchport provider interface switchport ethertype ether_type interface no n...

Страница 67: ...t1 g8032 no ring id g8032 no timer hold off g8032 no timer guard g8032 no timer wtr g8032 show ethernet ring g8032 status g8032 show ethernet ring g8032 brief g8032 show ethernet ring g8032 port statu...

Страница 68: ...spanning tree stp interface show spanning tree mode configure show spanning tree priority configure show spanning tree forward time configure show spanning tree hello time configure show spanning tree...

Страница 69: ...able configure event smtp warm start enable configure event smtp authentication failure enable configure event smtp erps change enable configure event smtp interface INTERFACE_NAME up down configure n...

Страница 70: ...figure show event syslog warm start configure show event syslog authentication failure configure show event syslog erps change configure show event syslog interface INTERFACE_NAME up down configure ev...

Страница 71: ...username configure no smtp authentication password configure no smtp receive 1 2 3 4 configure show smtp state configure show smtp sender configure show smtp subject configure show smtp server address...

Страница 72: ...igure snmp trap v3 level auth noauth priv configure snmp trap v3 engine ID engineID configure snmp trap v3 auth md5 sha PASSWORD configure snmp trap v3 encryption des aes PASSWORD configure no snmp tr...

Страница 73: ...s queue schedule strict wrr configure qos map cos priority_type to tx queue queue configure qos map dscp priority_type to tx queue queue configure qos trust cos dscp interface qos default cos cos_defa...

Страница 74: ...ast member count configure no igmp snooping last member interval configure no igmp snooping querier configure no igmp snooping fast leave interface show igmp snooping mdb configure show igmp snooping...

Страница 75: ...config usb path Fill in the folder and filename behind the copy startup config usb command Ex file1 folder file2 3 CLI enable configure terminal copy usb startup config path Fill in the folder and fi...

Страница 76: ...me behind the copy usb startup config command Ex file1 folder file2 5 CLI enable configure terminal Syslog mode usb or all Select USB or ALL it can auto save waning file to USB And the file name is me...

Страница 77: ...Rate 14 880 pps for 10Base T Ethernet port 148 800 pps for 100Base TX Fast Ethernet port Packet Buffer 1Mbits MAC Table 8K Jumbo Frame Flow Control IEEE 802 3x for full duplex mode back pressure for...

Страница 78: ...EMI FCC Class A EMS CE EN6100 4 2 3 4 5 6 8 CE EN6100 6 2 EN6100 6 4 Stability Testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration Safety UL 61010 1 UL 61010 2 201 Antaira Custo...

Отзывы: