EN
15
Remove the junction box on the back of the lamp. Adjust the position so that it fits the detector.
Fasten the junction box on the wall. The best installation height is from 2–3 metres. A lower height
can reduce functionality.
1.
Insert the power cord through the grommet in the junction box.
2.
Connect the brown wire to the L terminal and the blue wire to the N terminal.
3.
Check that the terminals are properly connected and tightened. Incorrect connection will
damage the detector.
4.
Refit the junction box on the lamp.
5.
Undo the plastic dome on the lamp and screw in a light source.
6.
Refit the plastic dome.
IMPORTANT:
Make sure the mains supply is disconnected when replacing the light source.
USE
Timing
The timer is located on the bottom of the sensor
unit. The timing controls how long the lamp
is to remain switched on (from 5 seconds to
7 minutes) after it has been activated by the
motion detector.