EN
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
ACTION
Pilot flame will not light.
Closed gas valve.
Open the gas valve.
Gas cylinder empty.
Replace with a full gas cylinder.
Clogged valve.
Clean or replace the valve.
Air in the gas system.
Bleed all lines.
Loose connections.
Check all connections.
Pilot flame lights but goes out.
Dirt around the pilot burner.
Clean.
Loose connections.
Tighten the connections.
Damaged thermostat.
Replace the thermostat.
Leaking gas line.
Check the connections.
Low fuel pressure.
Replace with a full gas cylinder.
The burner will not light.
Low pressure.
Replace with a full gas cylinder.
Clogged valve.
Remove and clean.
Knob not in ON position.
Turn the knob to ON position.
Damaged thermostat.
Replace the thermostat.
Bent pilot burner unit.
Adjust the pilot burner unit.
Unsuitable location.
Place in the correct position and try again.
NOTE:
Never attempt to dismantle or repair the gas heater yourself. Contact a qualified service technician if you have a problem.
Specifications
GAS CATEGORY
I3+(28-30/37)
I3B/P(30)
I3B/P(50)
TYPES OF GAS
Butane
Propane
LPG
LPG
GAS PRESSURE
28–30 mbar
37 mbar
30 mbar
50 mbar
OUTLET PRESSURE OF REGULATOR
30 mbar
30 mbar
30 mbar
50 mbar
The outlet pressure of the gas regulator must comply with the requirements for the relevant gas category as per above table.
Injector table
GAS CATEGORY
I3+(28-30/37)
I3B/P(30)
I3B/P(50)
TYPES OF GAS
Butane
Propane
LPG
LPG
GAS PRESSURE
28–30 mbar
37 mbar
30 mbar
50 mbar
TOTAL HEAT OUTPUT (Hs) (Qn)
13kW (G30: 945g/h; G31: 929g/h)
INJECTOR SIZE
1.90 mm for main burner
1.70 mm for main burner
0.18 mm for pilot burner
0.18 mm for pilot burner
Example of marking: 1.90 on the injector indicates an injector size of 1.90 mm.