least 25 % of the wall surface is open.
• The gas heater must not be used in enclosed
areas – this could result in personal injury or
death.
• Do not use the gas heater indoors – risk of
personal injury and/or material damage.
• Flammable substances or objects must not be
placed closer than 1 m above the gas heater and
1 m on all sides.
• Place the gas heater on a level, solid surface.
Anchor the gas heater to prevent it from blowing
over.
• Do not use the gas heater in explosive
environments, such as in the vicinity of
flammable liquids, gas or dust.
• The gas regulator and gas hose must be placed
so that there is no risk of tripping over them, or
chaffing.
• Turn off the gas heater and wait until it has
cooled before moving it.
• Do not move the appliance when in operation.
• Shut off the valve at the gas cylinder or the
regulator before moving the appliance.
GAS
• Only use propane or butane, or a mixture of
these.
• The installation must comply with applicable
regulations for the storage and handling of LPG.
• Have the gas supplier check the gas cylinder if it is
dented, corroded or otherwise damaged. Never
use gas cylinders with damaged valve
connections.
• The gas cylinder must be positioned so that gas
cannot accumulate around the bottle.
• An LP cylinder not connected for use shall not be
stored in the vicinity of this or any other
appliance.
• Never connect a non-approved gas cylinder to the
heater.
• Keep the appliance at least 1m from the gas
cylinder.
• Do not connect the gas cylinder directly to the
appliance without regulator. Use only the type of
gas and the type of cylinder specified in the
instructions.
• A regulator(compliees with EN16129:2013 and
the national regulation) of the correct pressure
corresponding to the appliance category.
• Use 30mbar regulator for butane/propane under
the category I3B/P(30).
• Use 30mbar regulator for butane under the
category I3+(28-30/37).
• Use 37mbar regulator for propane under the
category I3+(28-30/37).
• Use 50mbar regulator for butane/propane under
the category I3B/P(50).
• It's recommended to use flexible hose that
approved by EN16436: 2014.
WARNING!
• Accessible parts can be hot.
• Keep children at a safe distance.
• Keep clothing and furniture away from the gas
heater.
• Wear safety gloves when handling hot parts.
TECHNICAL DATA
Output
13 kW
Fuel consumption
945 g/h
Gas hose
1.4 m approved as per ISO 3821
Gas cylinder
P11/PC10
Size
222.2 x Ø 81.3 cm
Weight
15 kg
Gas regulator sold separately. Gas cylinder sold separately.
For further information, see data sheet in the manual.
DESCRIPTION
1. Reflector
2. Stud
3. Burner
4. Gas hose
5. Cylinder cover
6. Pillar
7. Cylinder support
8. Base plate
9. Wheel
FIG. 1
10. Flange nut M8
x2
11. Screw M8 x 16
x5
12. Flange nut M6
x6
13. Screw x4
14. Screw M6 x 30
x6
15. Stud
x3
Содержание 411105
Страница 3: ......
Страница 4: ...1 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21...
Страница 5: ...3 4 5 6...
Страница 6: ...7 8 9...
Страница 7: ...10...