EN
18
TECHNICAL DATA
Rated voltage
230 V ~ 50 Hz
Input power
35.97 W
Operating value
0.13 (m³/min)/W
Power consumption in standby mode (Psb)
0.39 W
Annual power consumption
11.95 kWh
Safety class
II
Protection rating
IPX0
Operating temperature
16–38°C
Sound power level, LwA
48.16 dB
Max air speed
4.57 m³/min
Max flow speed
3.72 m/s
Battery for remote control
CR2025
Cord length
160 cm
Operating value standard
IEC 60879:1986 (corr. 1992)
DESCRIPTION
1. Control panel
2. Handle
3. Air inlet
4. Foot
5. Air outlet
6. Display
FIG. 1
Remote control
Button
Function
POWER
Starts and switches off the fan.
SPEED
Adjusts the speed in the
sequence 0-I-II-III.
OSC
Enables/disables oscillation
mode.
TIMER
Enables the timer function
(0.5–7.5 h).
MODE
Switches mode.
FIG. 2
INSTALLATION
NOTE:
The fan foot must be fitted before use.
1. Carefully unpack all the fan parts and
check that nothing is missing.
2. Place the fan upside down on a cushion
or soft towel. It is easier if another person
holds the fan while fitting it.
3. Place the top part of the foot on the fan
base and align it to three of the guides on
the column.
4. Place the bottom part of the foot over
the top part. Make sure not to clench the
power cord.
5. Screw the foot on the fan with the 4 long
screws and screw the two parts of the foot
together with the 2 short screws.
6. Put the power cord through the guide (A)
so that it is flush with the underside of the
foot and comes out through the opening
in the side.
FIG. 3
USE
1. Place the fan on a dry, horizontal surface.
2. Plug the plug in a power point.
3. Start the fan by pressing POWER on the
remote control or the control panel. The
corresponding status light on the top of
the fan goes on. Switch off the fan by
pressing POWER again.
4. Adjust the speed by pressing SPEED on
the remote control or control panel. The
corresponding status light on the top of
the fan goes on.
Содержание 004840
Страница 3: ...1 2 1 2 3 4 5 6 ...
Страница 4: ...3 4 5 A ...