![ANSIMAG K+1516 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/ansimag/k-1516/k-1516_installation-and-maintenance-manual_2945561032.webp)
32
10-c. Aligning Pump Mounting Feet
Set the complete pump assembly on its feet on a flat surface. Ensure that all feet are flat on the surface.
This may require slightly loosening the bolts at the three piloted joints – the rear support to pump case,
the bracket to rear support and the bracket to motor mounting plate. Adjust the clocking of the parts at
these joints as required to get all feet to sit flat. This may require lightly tapping on any foot not in
contact with the flat surface, or tapping on the parts adjacent to the joints. Re-snug all bolts. Then
torque all bolts in increasing torque values in a star pattern at each joint. Final torque at all three joints
is 40 ft-lb (54N-m.)