IP Network Measurement Division
5
40G Quick Start Guide
(
Jitter
)
40
40
G Jitter Measurement System Configuration (2/3)
G Jitter Measurement System Configuration (2/3)
MP1797A Jitter Analyzer
MP1797A Jitter Analyzer
MP1797A 40G Jitter Analyzer
Operation Frequency
: 39.81312G bit/s
43.0184 G bit/s
Jitter modulation frequency: up to 320MHz
Optical output power
: 0 – 3 dBm (typical)
Optical input sensitivity : -10 dBm (BER 10
-12
)
Measurement items
: Jitter generation,
Jitter transfer,
Jitter tolerance
IP Network Measurement Division
6
40G Quick Start Guide
(
Jitter
)
40G BER Measurement System Configuration (3/3)
40G BER Measurement System Configuration (3/3)
Operation Frequency
: 25G to 43.5G bit/s
Data Output level
: 2.0V fix
: 1.00 to 2.60V ( with option 01)
Input sensitivity
: >=100mV ( 70mV typical )
Evaluation pattern
: PRGM ( 512Mbits )
: PRBS ( 2
N
-1 : N=7, 9, 11, 15, 20, 23, 31 )
other features
: Cross point adjust (with option 01)
Burst Signal measurement for optical circulation loop test
43.5G bit/s BERT System
MP1800A
10Gbit/s 4ch PPG
MP1800A
10Gbit/s 4ch ED
MP1803A / MP1804A
43.5Gbit/s MUX / DEMUX
3