background image

19 / 45

(3) Set Tx CTRL Value

Choose a Tx CTRL Value.
It recommends “---> DNU” because  LCAS equipment also become “DNU” when it receive MST-Fail.

5.

5.

Measurement 

Measurement 

-

-

LCAS test (2)

LCAS test (2)

(4) Negotiation ON

Check this box to start LCAS negotiation. 

 

20 / 45

(5) Check a current LCAS status

It is possible to check a summary of LCAS condition for both Source and Sink side like channel, 
SQ, MST, CTRL and so on in real time. Before change add/remove channel, you should confirm 
a current status of LCAS. You can also get a status of each channel as graphic in Status mode.

5.

5.

Measurement 

Measurement 

-

-

LCAS test (3)

LCAS test (3)

If you need GID, Rs-
Ack and Invert 
information, use 
monitor screen.

 

 10

Содержание MP1590B

Страница 1: ...Quick Start Guide MP1590B Network Performance Tester EoS Measurement...

Страница 2: ...NFIDENTIAL 1 Copyright 2005 by ANRITSU CORPORATION The contents of this manual shall not be disclosed in any way or reproduced in any media without the express written permission of Anritsu Corporatio...

Страница 3: ...asurement Quick Start Guide Anritsu Corporation IP Network Div First edition MBP 1SG050233 00 2 45 Before using MP1590B Before using MP1590B Requisite task before measuring Put in Key and Remote inter...

Страница 4: ...ions Save Load Printing and Screen Copy Switching between SDH and SONET 4 45 Put MP1590B on a safe and stable place where MP1590B is not fallen down on A cooling fan is situated on the rear panel of t...

Страница 5: ...r 1 Press the power switch for stand by condition 2 Turn off the main power switch Power Switch for Stand by condition Main Power Switch 1 1 Setup Setup Power Power On Off procedures On Off procedures...

Страница 6: ...hen GFP setting is required set Scramble ON OFF Ethernet Address of this port Extension Header parameters GFP FCS parameter of Rx side according to the DUT conditions This field changes according to t...

Страница 7: ...ec output power 1 to 3dBm input power 8 to 29 dBm 10 45 4 4 Setting Concatenation Setting Concatenation Contiguous Arbitrary Contiguous Arbitrary Setting contiguous concatenation parameters This setti...

Страница 8: ...has to choose Multiplexing It also has to choose Route when it use Low Order Concatenation HO VCAT LO VCAT 12 45 3 Detect VCG setting of DUT automatically Click the Detect VCG button in the Rx VCAT G...

Страница 9: ...t concatenation see 5 14 45 Multiplexing At first choose multiplexing from pull down menu If it set VC3 VC12 or VC11 it also choose Route from AU4 or AU3 Choose VCG size and Provisioned size automatic...

Страница 10: ...set concatenation see 5 Finish to set concatenation see 5 It is possible to change SQ for each channel in SQ Setting mode It is possible to choose channel across any AUG by this TAB in LO VCAT 16 45 5...

Страница 11: ...nish to set concatenation see section 5 Measurement It is possible to change SQ for each channel in SQ Setting mode It is possible to choose channel across any AUG by this TAB in LO VCAT 18 45 1 Setti...

Страница 12: ...tion 20 45 5 Check a current LCAS status It is possible to check a summary of LCAS condition for both Source and Sink side like channel SQ MST CTRL and so on in real time Before change add remove chan...

Страница 13: ...rator setting screen And choose command type at first 5 5 Measurement Measurement LCAS test 4 LCAS test 4 22 45 3 Choose target channel Next choose target channel of LCAS command in graphical screen a...

Страница 14: ...at the Generator tab 5 5 Measurement Measurement LCAS test 6 LCAS test 6 24 45 Capture LCAS command 1 Create LCAS send command Before capture set the capture parameters The following is recommend par...

Страница 15: ...counter counts B3 errors of each VCG member 1 Checking SDH SONET frame status MP1590B has 3 way to check status of SDH SONET Click Counter button then 2 counters are started One is counter other is VC...

Страница 16: ...atus of VCG This field is Quick View It is possible to display a history of status when it check History box 28 45 1 Inserting errors alarms When it inserts an error alarm in SDH SONET layer Click SDH...

Страница 17: ...when it check History box History Current 30 45 1 Monitor VCAT differential delay in Rx side It is possible to monitor VCAT differential delay in the Differential Delay Monitor in the SDH Rx tab It di...

Страница 18: ...current added delay value and pointer value This delay value is absolute 32 45 2 Add delay directly When it adds delay into VCG member directly it is possible to change delay value of VCG member with...

Страница 19: ...fferential delay test 4 Step Changes each Channel in turn Simultaneous Changes each Channel simultaneously Present 0 ms Target A 256 ms Target B 0 ms Repetition 1 2 3 Example 34 45 5 5 Measurement Mea...

Страница 20: ...Data Setting screen Click the Add button to register a new Tx stream The transmitted data contents MAC IP address transmitted load transmitted data repetition pattern are defined in the Tx stream Up...

Страница 21: ...Full wire rate of total bandwidth of provisioned channel 5 5 Measurement Measurement EoS test 2 EoS test 2 38 45 3 Setting frame data The Tx data contents protocol MAC IP address etc are set at the Fr...

Страница 22: ...e Error Insertion tab Error frames can be set independently for each GFP Ethernet IP TCP UDP layer 5 5 Measurement Measurement EoS test 4 EoS test 4 40 45 Checking received stream after setting Tx str...

Страница 23: ...n and select the frame to be displayed In this example frames 1 to 1000 will be displayed It indicate number of captured EoS frames Trigger Filter condition button 5 5 Measurement Measurement EoS test...

Страница 24: ...r does not select the target condition of load as the same target condition of save Target of save load Unit All module All port Module Port in selected module Port Selected port It will be an error i...

Страница 25: ...ossible to change SDH SONET in GUI Setting window Click Unit in Tree view by the right button and select GUI Setting in dropped menu Select SDH view SONET view at Standard in pop up window and click O...

Страница 26: ...EUR Italy Phone 39 06 509 9711 Fax 39 06 502 2425 Sweden ANRITSU AB Borgafjordsgatan 13 164 40 Kista Sweden Phone 46 853470700 Fax 46 853470730 Finland ANRITSU AB Teknobulevardi 3 5 FI 01530 Vantaa F...

Отзывы: