Anritsu MP1590B-30 Скачать руководство пользователя страница 2

 

Safety Symbols 

To prevent the risk of personal injury or loss related to equipment malfunction, Anritsu Corporation uses the follow-

ing safety symbols to indicate safety-related information.  Insure that you clearly understand the meanings of the 

symbols BEFORE using the equipment.    Some or all of the following five symbols may not be used on all Anritsu 

equipment.    In addition, there may be other labels attached to products which are not shown in the diagrams in 

this manual. 

 

Symbols used in manual 

DANGER 

 

This indicates a very dangerous procedure that could result in serious injury or 
death if not performed properly. 

 

WARNING 

 

This indicates a hazardous procedure that could result in serious injury or death if 
not performed properly. 
 

CAUTION 

 

This indicates a hazardous procedure or danger that could result in light-to-severe 
injury, or loss related to equipment malfunction, if proper precautions are not taken. 

 

Safety Symbols Used on Equipment and in Manual 

The following safety symbols are used inside or on the equipment near operation locations to provide information 

about safety items and operation precautions.    Insure that you clearly understand the meanings of the symbols   

and take the necessary precautions BEFORE using the equipment. 

 
 

 

This indicates a prohibited operation.    The prohibited operation is indicated sym-
bolically in or near the barred circle. 

ii 

 
 

 

This indicates an obligatory safety precaution.    The obligatory operation is indi-
cated symbolically in or near the circle. 

 
 

 

This indicates warning or caution.    The contents are indicated symbolically in or 
near the triangle. 

 
 

 

This indicates a note.    The contents are described in the box. 

 
 
 

 

These indicate that the marked part should be recycled. 

 

 
MP1590B-30 
High Precision Jitter Analysis 
Operation Manual 
 
2 March  2004 

(First 

Edition) 

10 June 

2009 (Fourth 

Edition) 

 
Copyright © 2004-2009, ANRITSU CORPORATION. 
All rights reserved.    No part of this manual may be reproduced without the prior written permission of the 
publisher. 
The contents of this manual may be changed without prior notice. 
Printed in Japan 

Содержание MP1590B-30

Страница 1: ...ead this manual before attempting to use the equipment Additional safety and warning information is pro vided within the MP1590B Network Performance Tester Operation Manual Please also refer to this d...

Страница 2: ...Used on Equipment and in Manual The following safety symbols are used inside or on the equipment near operation locations to provide information about safety items and operation precautions Insure th...

Страница 3: ...se or unauthorized modification or repair of the equipment by the customer The fault is due to severe usage clearly exceeding normal usage The fault is due to improper or insufficient maintenance by t...

Страница 4: ...s country of origin for re export from your country Before re exporting the product or manuals please contact us to confirm whether they are export controlled items or not When you dispose of export...

Страница 5: ...g 1 Product Model Option MP1590B 30 High Precision Jitter Analysis 2 Applied Directive and Standards When the MP1590B 30 High Precision Jitter Analysis are installed in the MP1590B the applied directi...

Страница 6: ...Model Option MP1590B 30 High Precision Jitter Analysis 2 Applied Directive and Standards When the MP1590B 30 High Precision Jitter Analysis are installed in the MP1590B the applied directive and stand...

Страница 7: ...Unit Rx Narrow MU150123A 10 10 7G Optical Unit Rx Wide MU150134A 10 10 7G Optical Unit Tx Ex Mod Operation Manual Explains specification for EO OE module Shows this document Explains specification for...

Страница 8: ...Operation Manual Explains specification for MP1590B 30 MP1590B 30 High Precision Jitter Analysis Operation Manual Explains operation for the software that monitors traffics on Ethernet Application Tr...

Страница 9: ...III This Operation Manual supports MP1590B 30 High Precision Jitter Analysis for MP1590B It is explained in the text in the case of MP1590B 30 High Precision Jit ter Analysis...

Страница 10: ...This Manual I Chapter 1 Overview 1 1 1 1 Overview 1 2 1 2 O 172 New Recommendation and Verification Method for Jitter Measurement Accuracy 1 2 1 3 Product Configuration 1 3 Chapter 2 Specifications 2...

Страница 11: ...des an overview and describes the product configura tion of the MP1590B 30 High Precision Jitter Analysis 1 1 Overview 1 2 1 2 O 172 New Recommendation and Verification Method for Jitter Measurement A...

Страница 12: ...was adopted in the ITU T O 172 April 2005 Therefore this method is Global Standard of the Jitter measurement in strument 1 2 O 172 New Recommendation Verification Method for Jitter Measurement Accura...

Страница 13: ...on Verification Method for Jitter Measurement Accuracy Ch4 Reference clock Ch3 Optical data Data Trigger Pattern sync signal O 172 Phase Analysis Method Clock DUT Sampling oscilloscope Pulse pattern g...

Страница 14: ...Main Frame MU150100A 10 10 7 G unit MU150110A Multirate unit 2 MU150134A 10 10 7 G Optical unit Tx Ex Mod MU150123A 10 10 7 G Optical unit Rx wide MU150123B 10 10 7 G Optical Electrical unit Rx wide...

Страница 15: ...Chapter 2 Specifications 2 1 This chapter provides the specifications of the MP1590B 30 High Preci sion Jitter Analysis 2 1 Specifications 2 2...

Страница 16: ...ement conditions Measurement time 1 min Average 5 measurements Filter 10 G 20 kHz to 80 MHz 50 kHz to 80 MHz 2 5 G 5 kHz to 20 MHz 12 kHz to 20 MHz Transmitter MU150121A B MU150134A or an optical tran...

Страница 17: ...as a reference value for the meas urement accuracy Item 1 2 2 Measurement conditions Filter 10 G 20 kHz to 80 MHz 50 kHz to 80 MHz 2 5 G 5 kHz to 20 MHz 12 kHz to 20 MHz Pattern OC 192c STM 64c J0 Z0...

Страница 18: ...asurement time 1 min Filter 10 G 20 kHz to 80 MHz 50 kHz to 80 MHz 4 MHz to 80 MHz 2 5 G 5 kHz to 20 MHz 12 kHz to 20 MHz 1 MHz to 20 MHz Pattern OC 192c STM 64c OC 48c STM 16c Payload PRBS23 31 Optic...

Отзывы: