MU120131A/32A PON Quck Start Guide
19
(3) Selecting Field Conditions
At the [Field Setting] screen, select the allocation conditions. Here, first, allocation is
performed using the destination address so select
“MAC DA (32bit)” and press “Edit…”.
When
“MAC DA” is “00-00-00-00-00-24”, looking at the last 16 bits of “-00-24”, when
“Format:” is “Hexadecimal”, “Offset:” becomes “32” and “Length:” becomes “16”.
Press
“OK”.
Put a checkmark in
“MAC DA (16bit)” and press “OK” to confirm.
* The Field setting supports up to 16 bit×4 Block. When Offset is divided by 8 and the sum
of the remainder and Length exceeds 16 bits, it becomes 1 Block. The above setting
is 2 Blocks.
[{Offset(32)÷8 = remainder 0} + {Length(16)}]÷16 =12 Blocks