ArcPower 192 Outdoor US
7
3.4 Setting and control
For setting DMX address, selecting DMX mode and for another settings you need either Robe Universal Interface
or RDM Communicator. Please see the Robe Universal Interface or RDM Communicator user manuals to get more
information about this products. The way, how to connect these interfaces to the DMX data link is figured below.
NOTE
: Do not connect the RDM communicator and the The Robe Universal Interface to the fixture at the same
time.
1.Robe Universal Interface
2. RDM Communicator
Note: DMX controller has to be disconnected from the fixture when the RDM communicator is operated.
3.5 DMX 512 connection
To build a DMX chain
1.
Connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain.
2.
Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture.
3.
Always connect the DMX output with the input of the next fixture until all fixtures are connected.
Do not overload the link. Max. 32 fixtures may be connected on a DMX link.
Caution: Terminate the output of the last fixture with a 120 Ohm resistor wired betwen data (+) and data (-) in
order to ensure the proper transmission on the data link.