ArcPower 192 Outdoor US
5
3. Installation
3.1 Mounting the fixture
Ensure that the structure (truss, wall) to which you are attaching
the unit is secure.
Fixture must be installed by a qualified electrician in accordance with all national and local electrical and
construction codes and regulation.
The ArcPower 192 Outdoor US can be arranged in any position orientation.
The housing of the control unit offers two mounting holes, each with a diameter of 13mm .
Caution:
Overhead installation requires experience. Fixtures may cause severe injuries when crashing down! If you
have doubts concerning the safety of a possible installation, do not install the device and consult installation with
an expert.
3.2 Connection to the mains
The ArcPower 192 Outdoor US uses a 5-cored power/data cable. The 3 cores serve for the power supply and next
2 shielded cores are intended for DMX connection:
Core
Connection
Core
Connection
Black
Live
Red
Data +
Blue
Neutral
White
Data -
Yellow/Green
GND
PE
Shielding
0
Connect the junction box to mains and DMX acording to the tables below
Power connection
L
N
GND/PE
EU
Braun
Blue
Green/yellow
US
Black
White
Green
This device falls under class one and must be grounded!
DMX connection
+
0
-
Data +
Data ground(shielding)
Data -
Содержание ArcPower Outdoor 192 US
Страница 1: ...Version 1 6...