background image

ArcPad Zoom 48MC 

 

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY 

BEFORE POWERING OR INSTALLING YOUR  ArcPad Zoom 48MC! 

Save it for future reference.

 

 

This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a 
safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in 
this manual. 
 
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual 
or any unauthorized modification to the device. 
 
Please consider that damages caused by manual modifications to the device are not subject to warranty. 
 
This device is for professional use only. It is not for household use. 

 

1. Safety instructions 

 

DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT! 

 

Make sure that the available voltage is not higher than stated on the rear side of the fixture. 
This fixture should be operated only from the type of power source indicated on the marking label. If you are not 
sure of the type of power supplied, consult your authorized distributor or local power company. 
 
Always disconnect the fixture from AC power before cleaning, removing or installing the  fuses, or any part. 
 
 Do not overload supply line as this can result in fire or electric shock.  
 
Make sure that the power/data cable is never crimped or damaged by sharp edges. Check the fixture and the 
power/data cable from time to time. 
 
Do not install the unit near naked flames. 
 
Refer servicing to qualified service personnel. 
 

This fixture falls under protection class I. Therefore this fixture has to be connected to a mains socket outlet with 
a protective  earthing connection. 

 
Do not connect this fixture  to a dimmer pack. 

 

 
Warning! Risk Group 2 LED product according to EN 62471

.

 

LED light emission. Risk of eye injury. 
Do not look straight at the fixture´s  LEDs during operation. The intense light beam may damage your eyes. 
 

Keep compustible materials at least 0.2 m away from the fixture. 

 

If the fixture has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on 
immediately. The arising condensation water might damage your device. Leave the device switched off until it has 
reached room temperature. 
 
 Avoid brute force when installing or operating the fixture. 
 

Содержание ArcPad Zoom 48MC

Страница 1: ...Version 1 1...

Страница 2: ...rcPad Zoom 48MC RGBW DMX protocol 8 5 Control menu map RGBW version 10 6 Control menu 13 6 1 Addressing DMXA 13 6 2 Fixture information Info 13 6 3 Personality Pers 14 6 4 Manual Control Manual 14 6 5...

Страница 3: ...f the type of power supplied consult your authorized distributor or local power company Always disconnect the fixture from AC power before cleaning removing or installing the fuses or any part Do not...

Страница 4: ...ture becomes very hot during operation Allow the fixture to cool approximately 30 minutes prior to manipulate with it Operate the fixture only after having familiarized with its functions Do not permi...

Страница 5: ...altering its operation characteristics The LED module can be tilted to desired position by means of the tilt lock Use an Allen key 6 to adjust desired tilt position Three slots in the mounting bracket...

Страница 6: ...e with all national and local electrical and construction codes and regulations This device falls under class one and must be grounded The ArcPad Zoom 48 MC is equiped with with a 5 cored power data c...

Страница 7: ...e 3 x 1 5mm2 You have to take into account the the length of power data cable circuit breaker etc at projecting of the fixtures installation 3 3 Wireless DMX operation The wireless version of the ArcP...

Страница 8: ...nction stop in DMX value for at least 3 sec Zoom reset Reserved step step step step step step step 2 2 0 255 Red Cyan coarse Red LEDs saturation control 0 100 proportional 3 0 255 Red Cyan fine Red LE...

Страница 9: ...nbow effect with fade time from min max speed Rainbow effect without fade time from min max speed step step step step step step step step proportional step proportional step proportional step proporti...

Страница 10: ...l 6 Level 7 DMXA Set DMX address 001 255 DMX Pres Mode 1 Mode 2 Info POn Time Total Reset DMX In Powr 0 255 Dimm F 0 255 Temp Current High Res Highest Sw Ver IC 1 IC 2 IC 3 WL Pers DMX Pres Mode 1 Mod...

Страница 11: ...evel 6 Level 7 C Mix M RGBW CMY Dimmer SqL Linear Temp Uni C F I Ef Pos Powr Dimm F Store Defaults Manual Powr Dimm F Test Prg Sta Alone Auto Run Off Test User Pr Play Test Prg User Prg Pr Edit Step 1...

Страница 12: ...ArcPad Zoom 48MC 12 Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7 Wireless Stat Unlink Adjust DMX Val Powr 0 255 Dimm F 0 255 Calib Red Green Blue Whit Store Load d C Sw Upd On Off...

Страница 13: ...ntly from any other fixture on the DMX data link If there is no data received at the DMX input the display will start to flash 0001 with actually stored DMX address DMX Pres DMX preset Use the menu to...

Страница 14: ...r turn it off two minutes after last pressing any button on the control panel Contrast Use this function to adjust contrast of the display 0 100 Backlight Use this function to adjust backlight of the...

Страница 15: ...To edit program Procedure 1 Press UP or DOWN to select the menu Pr Edit and press ENTER 2 Press UP or DOWN to select the desired program step and press ENTER button 3 Press UP or DOWN to select the d...

Страница 16: ...ram to the folder II Fixture software updating 1 Determine which of your ports is available on your PC and connect it with the DMX input of the fixture if you using the flash cable RS232 DMX with the...

Страница 17: ...ted RDM controller to send commands to and receive messages from specific moving lights RDM allows explicit commands to be sent to a device and responses to be received from it The list of commands fo...

Страница 18: ...els Operations modes DMX Stand alone Manual control of all effects via control panel One editable program up to 40 steps Wireless DMX RDM module only for ArcPad Zoom 48MC W Compliance with USITT DMX 5...

Страница 19: ...rcPad Zoom 48MC 19 Temperatures Ambient temperature range 20 C 40 C Maximum housing temperature 70 C Total heat dissipation 440 BTU h calculated Weight 11 6 kg fixture 1 5 kg floor stand Dimensions mm...

Страница 20: ...rcPad Zoom 48MC 20 Junction box Included items 1 x ArcPad Zoom 48MC 1 x Junction box P N 99714080 1 x Data power cable 1 x User manual Optional accessories Floor stand for ArcPad Zoom 48MC P N 1098023...

Страница 21: ...aintenance and service operations are only to be carried out by a qualified person Should you need any spare parts please use genuine parts 9 1 Replacing a fuse This replacement has to be realized by...

Страница 22: ...ArcPad Zoom 48MC 22...

Отзывы: