background image

Table of lubricants 

The pump is delivered complete with  high-performance 

30

 weight, non-detergent oil  suitable for the 

intended ambient conditions (see "Environmental operating limits"). 

Inspecting the pump mounting 

Check that the pump's fixing screws have not become loose. 

If necessary, tighten them with the driving torque stated in the installation design. 

Inspecting the connections and pipes 

- Inspect the connections for leaks.

Leaks can normally be dealt with by tightening the connections properly. 

If leaks from the intake pipeline connections are noticed, the seals must be repaired. 

- Inspect the hoses.

If the pipes show signs of aging, breakage, swelling, rubbing, etc., they must be replaced. 

Inspecting the Inlet Filter 

- Inspect the inlet filter cartridge.

If the cartridge is fouled, wash it thoroughly to remove the dirt.

If the cartridge is torn or cracked, it must be replaced.

Checking the oil level 

- Check  the  oil  with  the  pump  level,  ensuring 

that it has been running for at least 5 minutes in 
normal working conditions.

-

If the oil level is not visible or completely full, 

add or remove oil to restore this level and 
check, still with the pump running, that the oil 
level does not vary so much that it leaks from 
the cap or is no longer visible in the tank.

-

If necessary, top up with oil with A

/R

 

P

remium 

D

iaphragm 

P

ump oil 

P/

64

5

3

2

D

.

-

Check  the  oil  level  regularly,  as  it  may  vary 

significantly with the operating conditions.

To top up with oil proceed as described below. 

1)

Unscrew the cap and pour in oil

.

2) Screw the cap back into place.

�------

A

/R

 

P

ump 

O

il  

P/

N A

R64

5

32D

Содержание AR 1053

Страница 1: ...SP 27 1 102 4 725 50 12 1 68 8 AR1203 C C 30 6 115 8 725 50 13 6 68 8 AR1203 C SP 30 6 115 8 725 50 13 6 68 8 diAPHRAgm KiTS modeL deScRiPTion AR43309 BlueFlex AR43307 Desmopan AR43306 NBR AR43308 Vit...

Страница 2: ...o not draw in liquids at temperatures above 50 C or below 5 C Do not use the pump in drinking water supply systems Do not use the pump on products for human consumption Do not use the pump on pharmace...

Страница 3: ...diagram guideline The following is a simplified illustration of the typical installation layout and is purely a guideline Control Unit by pass Control Unit Delivery line filter Tank Agitation Pump In...

Страница 4: ...see Technical Data free from restrictions and elbows and with a filter of suitable capacity see Installation For occasional duty such as filling water supply tanks the pump can be operated at a vacuum...

Страница 5: ...issing ordamaged contact the dealer or manufacturer to agree the procedures to be followed The packaging material must be disposed of appropriately in accordance with the relevant statutory require me...

Страница 6: ...g a vacuum gauge to the pump intake fitting The rated pressure of the outlet hose fittings and clamps must be no less than the maximum rated pressure ofthe pump Replacing the intake and outlet fitting...

Страница 7: ...evel as described in the Checking the oil level section Before putting the pump into operation check that the control unit is set for low pressure Starting and stopping the pump To start the pump proc...

Страница 8: ...rtridge See Inspecting the filter Pump Checking the oil level See Checking the oil level Connection of pump to power Inspection Every working day source pulley belt coupling Pump Inspect mounting See...

Страница 9: ...placed Inspecting the Inlet Filter Inspect the inlet filter cartridge If the cartridge is fouled wash it thoroughly to remove the dirt If the cartridge is torn or cracked it must be replaced Checking...

Страница 10: ...he pump of products which are often corrosive and may damage its wetted parts over the long term If thepump is instorageduring the winter in locations with severe weather conditions it is very importa...

Страница 11: ...Restriction in intake circuit Intake filter fouled Intakecircuit not airtight Residual air left inside pump Valve plate stuck to its seat Pressure accumulator deflated Pressure accumulator deflated R...

Страница 12: ...t worn Oil pressure inside pump too high Restore correct oil level in tank One or more diaphragms ruptured Stop the pump at once Replace the diaphragms 1 Oil on pump body or base Pumpusing too much oi...

Страница 13: ...54 2 54 3 54 5 54 1 2021 AR North America 54 54 4 A R NORTH AMERICA A R NORTH AMERICA Version C C 82 81 81 AR 1053 AR 1203 Version C SP...

Страница 14: ...3 49 2680070 Sleeve 3 AR1053 2680080 Sleeve 3 AR1203 Pos Code Description Qty Note 50 550080 Diaphragm 3 NBR 550081 Diaphragm 4 BlueFlex 550084 Diaphragm 3 Viton 550085 Diaphragm 3 Desmopan 550086 Di...