2
2
If display p, means Pelco-P, the last two digital means baud rate. Define as follows
12 means 12 00bps,
24 means 2400bps,
48 means 4800bps,
96 means 9600bps.
Secondly, set up the band rate and protocol
When you press the
SETUP
button (more than three seconds), screen will display like or
, when your press up or down key, you can see d or P change at screen, you can modify baud
rate if you press right or left key, you can see 12/24/48/96 change at screen .Then press
ENTER
key can
save this configuration and return to normal mode.
NOTE: You can setup different protocol for different address, for example you can setup address 1 is
PLECO-D 2400bps, address 2 can be Pelco-P 9600bps. If you press C button, screen will black for 10
second, PTZ Controller will clean all protocol setup and setup all address to Pelco-D 2400bps.
2 Set up Address of the Camera
When you press CAM button, Screen display like
,
First A means address, another three digital
001 means the address number is 1, you can press number key input digital after A
Secondly, if the number is double digits, after you press the‘
-/--
’button then you can input the number
that
you need, then input the‘
ENTER
’button. The controller will display the number what you need.
Thirdly, if the number that you need is three digitals, you should input the number after you press the‘
-/--
’
button, the controller will display the number what you need. So you no need to press the‘
ENTER
’ button .
Firstly, if the number is one digit, you can input the number what you need directly
APPENDIX D CONTROLLER GUIDELINESS