background image

17

survey,a should be less than

the compliance level in each

frequency range.

b

Interference may occur in

the vicinity of equipment

marked with the following

symbol:

NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.

NOTE 2 These guidelines may not apply in all situations. Electromagnetic is

affected by absorption and reflection from structures, objects and people.

a. Field strengths from fixed transmitters, such as base stations for radio

(cellular/cordless) telephones and land mobile radios, amateur radio, AM and

FM radio broadcast and TV broadcast cannot be predicted theoretically with

accuracy. To assess the electromagnetic environment due to fixed RF

transmitters, an electromagnetic site survey should be considered. If the

measured field strength in the location in which the JPD-FR100+ Infrared

Thermometer is used exceeds the applicable RF compliance level above, the

JPD-FR100+ Infrared Thermometer should be observed to verify normal

operation. If abnormal performance is observed, additional measures may be

necessary, such as re-orienting or relocating the JPD-FR100+ Infrared

Thermometer.

b. Over the frequency range 150 kHz to 80 MHz, field strengths should be less

than 3 V/m.

Recommended separation distances between portable and mobile

RF communications equipment and the EQUIPMENT or SYSTEM -for

EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING

Recommended separation distances between portable and mobile RF

communications equipment and the JPD-FR100+ Infrared Thermometer.

The JPD-FR100+ Infrared Thermometer is intended for use in an

electromagnetic environment in which radiated RF disturbances are

controlled. The customer or the user of the JPD-FR100+ Infrared

Thermometer can help prevent electromagnetic interference by maintaining a

Содержание JPD-FR100+

Страница 1: ...JPD FR100 Infrared Thermometer Instruction Manual Manual Ver 1 2 Issuing Date 2018 01 29 0482 ...

Страница 2: ......

Страница 3: ...nd without the interference from ambient temperature The product will self test every time it starts up to make sure the normal operation and accuracy The Dual mode infrared thermometer JPD FR100 can be used to read the body temperature by measure the ear and forehead temperature which is suitable for adult and children ear test mode only for the child above 3 months Please read the instructions c...

Страница 4: ...re 3 5 How to measure the ear temperature 4 6 Instructions for display and operation 5 7 Cleaning and Disinfection 9 8 Maintenance 9 9 Troubleshooting 10 10 Technical specifications 11 11 After sale service 13 12 Security type 13 13 Authorized European Representative 13 14 Symbols 13 15 Declaration 14 16 Appendix A EMC Information Guidance and Manufacture s Declaration 14 ...

Страница 5: ...mometer for children rapid reading and simple operation compared with mouth thermometer Memory recall A maximum of 20 previous readings is available to help you track the changes of your body temperature Safe and hygienic Compared to mercury thermometer there is no danger of breaking the glass or swallowing mercury It is totally safe for children to use Fever warning When the reading exceeds 37 5 ...

Страница 6: ... Do not twist the Dual mode infrared thermometer and the temperature sensor Operating Conditions Temperature 10 C to 40 C Humidity 80 RH non condensing Atmospheric pressure 860hPa to 1060hPa Storage and Shipping Conditions Temperature 20 C to 55 C Humidity 95 RH non condensing Atmospheric pressure 50hPa to 1060hPa Battery Installation Put the two AAA batteries into battery compartment in correct p...

Страница 7: ...With the probe cover attached point the thermometer at the center of the forehead 2 Move the thermometer towards the forehead until the probe cover touches the skin The probe cover acts as a distance guide and ensures that the measuring distance between the thermometer and the forehead is correct 3 Press and release the Head button The temperature will be displayed on the screen instantly Note You...

Страница 8: ...conds as you will activate the memory recall mode Incorrect position Correct Position Figure 1 For children older than 1 year old gently pull the ear up to ensure that the ear canal is straight See Figure 1 Position the ear probe carefully so that it is aligned with the eardrum to ensure accurate measurement readings This applies to adults as well For children younger than 1 year old gently pull t...

Страница 9: ...ly evaporate before using the thermometer 2 Please use the thermometer indoor or in an environment where there is no strong air draft 3 Do not move during measurement 4 Make sure there isn t any sweat water or condensation on the forehead 5 If the thermometer is transferred from an environment where the ambient temperature may be different please wait at least 10 minutes and follow rule number 2 b...

Страница 10: ...tton The temperature will be displayed on the LCD screen 3 To measure again simply press the Head Ear button accordingly When the temperature is below 99 6 F 37 6 C 32 0 99 5 F 0 0 37 5 C there will be a long beep and a green backlit will be displayed for 3 seconds When the temperature is above 99 5 F 37 5 C 99 6 212 0 F 37 6 100 0 C there will be 7 short beeps and the reading will flicker with a ...

Страница 11: ...the next recorded reading press the Ear button again The number 2 with the M signal will be displayed After 1 second the recorded reading with the mode of measurement icon will be displayed Repeat to recall earlier recorded data up to 20 total readings if necessary None The LCD will display with the M signal blinking if there is no recorded data None C F conversion LCD display Operational steps So...

Страница 12: ...n the battery voltage is below2 61V 2 Please replace battery None Power Off Mode The thermometer will power off automatically if no activity is detected for 10 seconds Attention Electromagnetic interference JPD FR100 contains sensitive electronic component and shall not use under the condition with electromagnetic interference such as the place nearby the mobile phones and microwaves Please dispos...

Страница 13: ...ny part of the thermometer into liquid or allow liquid to enter the thermometer Disinfection 1 Disinfect the thermometer body and the area around the temperature probe with a cloth slightly moistened with 75 medical alcohol Do not use hot steam or ultraviolet radiation for disinfection Otherwise the thermometer may be damaged or quickly aged 8 Maintenance 1 After each use clean the temperature pro...

Страница 14: ...OVO or a local distributor Only the battery symbol is displayed after the thermometer powers on The battery level is low Use new batteries of the same model or specifications Er1 is displayed The ambient temperature is lower than 10 C 50 0 F or higher than 40 C 104 F Take a measurement under an ambient temperature between 10 C 50 0 F and 40 C 104 F ErC is displayed An error occurs when data is bei...

Страница 15: ...r is moved into the measurement environment The temperature reading is higher than the typical body temperature range The temperature probe is faulty Contact ANKOVO 10 Technical specifications Items Standards models Dual mode infrared thermometer JPD FR100 1 Applicable regulations and laws ASTM 1965 EN12470 5 2 Temperature units adjustable 3 Measurement range Forehead temperature mode 32 0 42 2 89...

Страница 16: ...ge display function The product shall display low voltage signal if the voltage is below 2 51V 0 15V 11 Memory function Memorize 20 groups of measured temperature 12 Current consumption Istand by 2μA Iworking 0 5mA IBuzzer on 2mA Ibanklight 15mA 13 LED backlit specifications 1 2cd m2 15 Operational conditions ASTM 10 40 50 104 15 95 RH 16 Type of measuring Applicable for forehead temperature and e...

Страница 17: ...e of 37 to 39 98 to 102 for IR thermometers is 0 2 0 4 whereas for mercuryin glass and electronic thermometers the requirement per ASTM Standards E 667 86 and E 1112 86 is 0 1 11 After sale service The device is under warranty for two years since the date of acquisition Application for repairing should be presented during the warranty period The damage caused by improper use is not under warranty ...

Страница 18: ...y with ISO10993 1 ISO10993 5 and ISO10993 10 16 Appendix A EMC Information Guidance and Manufacture s Declaration CAUTION JPD FR100 Infrared Thermometer needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided for in the ACCOMPANYING DOCUMENTS Portable and mobile RF communications equipment can affect JPD FR100 Infrared Thermo...

Страница 19: ...er s declaration electromagnetic immunity for all EQUIPMENT and SYSTEMS Guidance and manufacturer s declaration electromagnetic immunity The JPD FR100 Infrared Thermometer is intended for use in the electromagnetic environment specified below The customer or the user of the JPD FR100 Infrared Thermometer should assure that it is used in such an environment Immunity test IEC 60601 test level Compli...

Страница 20: ...liance level Electromagnetic environment guidance Radiated RF IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m Portable and mobile RF communications quipment should be used no closer to any part of the JPDFR100 Infrared Thermometer including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance where p...

Страница 21: ...n in which the JPD FR100 Infrared Thermometer is used exceeds the applicable RF compliance level above the JPD FR100 Infrared Thermometer should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating the JPD FR100 Infrared Thermometer b Over the frequency range 150 kHz to 80 MHz field strengths should be le...

Страница 22: ... 0 73 1 1 2 2 3 10 3 8 7 3 100 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation dista...

Страница 23: ......

Страница 24: ...Shenzhen Jumper Medical Equipment Co Ltd Address D Building No 71 Xintian Road Fuyong Street Baoan Shenzhen Guangdong China Website https ankovo com E mail cs ANKOVO com ...

Отзывы: