12
3283430_GB
WIRING
Mod.
…51MU – …52MU
The connection to power supply may be carried out at the
back of the appliance after removing the protection grid and
the box cover.
Mod. …101LU – …101SU – …72SU – …102SU
The connection to power supply may be carried out in the
upper part of the appliance after removing the protection
panel and the box cover.
All wiring cables are to comply with the ratings shown on the technical specifications
Cables are to be connected to the no potential difference terminal.
The grounding cable is to be directly connected to a good grounding system.
The guarantee will cease and the Manufacturer will not be liable for any damage to appliances or
operators arising from the non-compliance with the and tamperings to any part of the appliance
(electric, thermodynamic or hydraulic plant).
CONDENSATE DRAIN
The equipment has a condensation collection tray. The tray is extractable from the lower part of the
equipment.
TESTING
Should the appliance have been transported horizontally instead of a vertical position DO NOT START THE
APPLIANCE IMMEDIATELY. WAIT FOR AT LEAST
24 HOURS
BEFORE OPERATING.
The manufacturer declines any responsibility and any warranty obligation if damage occurs to the
equipment imputable to transportation in a horizontal position.
Carry out the following checkings:
1) Outside temperatures must be included between 59°F and 100°F.