The appliance is fitted with the controls for use of its
main functions.
A)Burner control knob
: for lighting, turning off
and regulating the relative burner and pilot
light.
B)Pilot light ignition button
.
C)Pilot light switch-off button
.
D)Piezoelectric ignition knob
: for lighting the pilot
light.
DESCRIPTION OF CONTROLS
Lighting
1- Turn on the gas supply tap.
2 - Turn knob
A
clockwise (pos.
a
) to light the pilot
light.
3 - Hold down button
B
and press the piezoelectric
ignition
C
repeatedly to light the pilot light. Hold
the knob down for about 15 seconds to trip the
thermocouple.
Note: check that the pilot light is lit through the inspection
slit (D).
4 - Turn the knob (
A
) clockwise (pos.
b
) to the tem-
perature required.
Turning off
1- Turn the knob (
A
) anti-clockwise (pos.
c
) to turn
off the burner.
N.B.: the pilot light will remain on to allow the burner to
be re-lit.
2 - Press button
E
to switch off the pilot light.
3 - Turn off the knob to ensure safety.
SWITCHING THE BURNER ON AND OFF
IDM-39604005100.tif
D
A
C
D
B
B
C
A
Pilot light
marker
Pilot light
marker
Off marker
Piezoelectric ignition
marker
Temperature marker
a
b
c
A
B
D
IDM-39604005200.tif
C
E