background image

3

Features                             

4

Positioning                          

4

Installation                                                 

6

Alarm Test                           

7

Alarm Pause                                              

8

Note: This user manual is also available in large text and other formats  
Please email: 

[email protected]

 or call 

0800 141 2561

 for 

further information 

CONTENTS

Battery Replacement               

8

Troubleshooting                                     

9

Maintenance                                         

10

Disposal                           

10

Warranty                                                    

11

Содержание SA700-AE-UK

Страница 1: ...1 y mar Title Description User Manual Material 60GSM Wood Free Paper Used On Used For SA700 AE UK Size W 120mm H 120mm Supplier PACE Print Colours CMYK User Manual Optical Smoke Alarm www angeleye com SA700 AE UK ...

Страница 2: ...echnicalsupport sprue com Web www sprue com Sprue Safety Products Ltd Vanguard Centre Coventry CV4 7EZ UK A Sprue Brand GN3563R1 SA700 AE UK Optical Smoke Alarm 0086 0086 CPR 597993 Smoke alarm devices EN 14604 2005 DOP 13 02 14 BS EN 14604 2005 Licence No KM597992 ...

Страница 3: ...arm Pause 8 Note This user manual is also available in large text and other formats Please email technicalsupport sprue com or call 0800 141 2561 for further information CONTENTS Battery Replacement 8 Troubleshooting 9 Maintenance 10 Disposal 10 Warranty 11 ...

Страница 4: ...ew build properties In this type of property the building regulations require alarms to be interlinked You can obtain further information from your local fire service or building control department at your local council offices These sources generally provide advice on new builds or projects that require planning permission Your smoke alarm typically meets the minimum requirements for family livin...

Страница 5: ...y hallways and landings Install smoke alarms in circulation areas at a distance no greater than 7 5m from the farthest wall no greater than 7 5m from a door to any room in which a fire might start and no greater than 7 5m from the next smoke alarm If it is necessary to place a smoke alarm on a wall always locate the detection element of the alarm 150mm to 300mm 6 to 12 inches below the ceiling and...

Страница 6: ...oke alarm is to be fitted it should be located horizontally on the ceiling either in the living room or the hall but not in the proximity of either kitchen or bathroom 2 Additional alarms can be fitted in bedrooms 3 DO NOT locate alarm close to exhaust fans or air conditioning INSTALLATION 4 Separate the alarm from the mounting plate This may require you to turn the alarm clockwise while holding t...

Страница 7: ... 7 Line up the arrow on the back of the alarm with the arrow inside the base plate and inset the alarm Once the alarm is inside the base plate twist it anti clockwise to lock it into place 8 Test the alarm ALARM TEST 1 Press and release the test button to test alarm The alarm should sound three times 2 After testing check that the red light flashes approximately every 40 seconds 3 Test the alarm o...

Страница 8: ...e feature by pressing the test button WARNING If there is any question as to the cause of an alarm always assume that this is due to an actual fire and follow your fire emergency plans Do not assume the alarm is a nuisance alarm BATTERY REPLACEMENT Your alarm requires two AAA LR03 alkaline batteries Under normal use the batteries should last approximately one year Low Battery Warning alarm beeps e...

Страница 9: ...emains steadily on or off Inspect for obvious damage Check the unit contains the recommended battery type and that it is properly connected If in doubt contact Technical Support on 0800 141 2561 or e mail technicalsupport sprue com The alarm beeps twice every 45 seconds This indicates a fault with the alarm Inspect for obvious damage Check the unit contains the recommended battery type and that it...

Страница 10: ...aint the smoke alarm as this may block the openings and prevent smoke from entering the sensor Storage in low humidity and certain transportation conditions may cause electrostatic charges to build up in the alarm system housing Although harmless they may increase the length of time that the horn sounds upon battery insertion or test button operation The condition may be cleared by gently wiping t...

Страница 11: ...om the date of original retail purchase and is not transferable Proof of purchase is required This warranty does not cover damage resulting from accident misuse disassembly abuse or lack of reasonable care of the product or applications not in accordance with the user manual It does not cover events and conditions outside of Sprue Safety Products Ltd s control such as Acts of God fire severe weath...