background image

11

Storage in low humidity, and certain 
transportation conditions, may cause 
electrostatic charges to build up in 
the alarm system housing  Although 
harmless, they may increase the length 
of time that the horn sounds upon battery 
insertion or test button operation  The 
condition may be cleared by gently wiping 
the inside and outside of the plastic cover 
with a clean, damp cloth 

DISPOSAL

Waste electrical products should not be disposed 
of with your other household waste  The alarm is 
ideally suited for disposal within the waste electronic 
and electrical equipment (WEEE) recycling scheme  
Please recycle where facilities exist  Check with 
your local authority, retailer or contact our Technical 
Support team for recycling/disposal advice, as 
regional variations apply 

WARNING:

 Do not burn or dispose of 

 

in fire 

WARNING:

 If your alarm is dropped or damaged, as 

a precaution, it should be removed from the building 

WARRANTY

Sprue Safety Products Ltd warrants to the original 
purchaser that its enclosed smoke alarm be free 
from defects in materials and workmanship under 
normal residential use and service for a period of 5 
(five) years from the date of purchase  Provided it is 
returned with postage prepaid and proof of purchase 
date, Sprue Safety Products Ltd hereby warrants that 
during the 5 (five) year period commencing from the 
date of purchase Sprue Safety Products Ltd, at its 
discretion, agrees to replace the unit free of charge  
The warranty on any replacement SA700 alarm, will 
last for the remainder of the period of the original 
warranty in respect of the alarm originally purchased 
– that is from the date of original purchase and not 
from the date of receipt of the replacement product  
Sprue Safety Products Ltd reserves the right to offer 
an alternative product similar to that being replaced 
if the original model is no longer available or in stock  
This warranty applies to the original retail purchaser 
from the date of original retail purchase and is not 
transferable  Proof of purchase is required 
This warranty does not cover damage resulting 
from accident, misuse, disassembly, abuse or lack 
of reasonable care of the product, or applications 
not in accordance with the user manual  It does not 
cover events and conditions outside of Sprue Safety 
Products Ltd’s control, such as Acts of God (fire, 
severe weather etc )  It does not apply to retail stores, 
service centres or any distributors or agents  Sprue 
Safety Products Ltd will not recognise any changes to 
this warranty by third parties 

Sprue Safety Products Ltd shall not be liable for any 
incidental or consequential damages caused by the 
breach of any expressed or implied warranty  Except 
to the extent prohibited by applicable law, any 
implied warranty of merchantability or fitness for a 
particular purpose is limited in duration for 5 (five)
years 
This warranty does not affect your statutory rights  
Except for death or personal injury, Sprue Safety 
Products Ltd shall not be liable for any loss of use, 
damage, cost or expense relating to this product 
or for any indirect, or consequential loss, damages 
or costs incurred by you or any other user of this 
product 

Содержание SA700-AE-UK

Страница 1: ...1 y mar Title Description User Manual Material 60GSM Wood Free Paper Used On Used For SA700 AE UK Size W 120mm H 120mm Supplier PACE Print Colours CMYK User Manual Optical Smoke Alarm www angeleye com SA700 AE UK ...

Страница 2: ...echnicalsupport sprue com Web www sprue com Sprue Safety Products Ltd Vanguard Centre Coventry CV4 7EZ UK A Sprue Brand GN3563R1 SA700 AE UK Optical Smoke Alarm 0086 0086 CPR 597993 Smoke alarm devices EN 14604 2005 DOP 13 02 14 BS EN 14604 2005 Licence No KM597992 ...

Страница 3: ...arm Pause 8 Note This user manual is also available in large text and other formats Please email technicalsupport sprue com or call 0800 141 2561 for further information CONTENTS Battery Replacement 8 Troubleshooting 9 Maintenance 10 Disposal 10 Warranty 11 ...

Страница 4: ...ew build properties In this type of property the building regulations require alarms to be interlinked You can obtain further information from your local fire service or building control department at your local council offices These sources generally provide advice on new builds or projects that require planning permission Your smoke alarm typically meets the minimum requirements for family livin...

Страница 5: ...y hallways and landings Install smoke alarms in circulation areas at a distance no greater than 7 5m from the farthest wall no greater than 7 5m from a door to any room in which a fire might start and no greater than 7 5m from the next smoke alarm If it is necessary to place a smoke alarm on a wall always locate the detection element of the alarm 150mm to 300mm 6 to 12 inches below the ceiling and...

Страница 6: ...oke alarm is to be fitted it should be located horizontally on the ceiling either in the living room or the hall but not in the proximity of either kitchen or bathroom 2 Additional alarms can be fitted in bedrooms 3 DO NOT locate alarm close to exhaust fans or air conditioning INSTALLATION 4 Separate the alarm from the mounting plate This may require you to turn the alarm clockwise while holding t...

Страница 7: ... 7 Line up the arrow on the back of the alarm with the arrow inside the base plate and inset the alarm Once the alarm is inside the base plate twist it anti clockwise to lock it into place 8 Test the alarm ALARM TEST 1 Press and release the test button to test alarm The alarm should sound three times 2 After testing check that the red light flashes approximately every 40 seconds 3 Test the alarm o...

Страница 8: ...e feature by pressing the test button WARNING If there is any question as to the cause of an alarm always assume that this is due to an actual fire and follow your fire emergency plans Do not assume the alarm is a nuisance alarm BATTERY REPLACEMENT Your alarm requires two AAA LR03 alkaline batteries Under normal use the batteries should last approximately one year Low Battery Warning alarm beeps e...

Страница 9: ...emains steadily on or off Inspect for obvious damage Check the unit contains the recommended battery type and that it is properly connected If in doubt contact Technical Support on 0800 141 2561 or e mail technicalsupport sprue com The alarm beeps twice every 45 seconds This indicates a fault with the alarm Inspect for obvious damage Check the unit contains the recommended battery type and that it...

Страница 10: ...aint the smoke alarm as this may block the openings and prevent smoke from entering the sensor Storage in low humidity and certain transportation conditions may cause electrostatic charges to build up in the alarm system housing Although harmless they may increase the length of time that the horn sounds upon battery insertion or test button operation The condition may be cleared by gently wiping t...

Страница 11: ...om the date of original retail purchase and is not transferable Proof of purchase is required This warranty does not cover damage resulting from accident misuse disassembly abuse or lack of reasonable care of the product or applications not in accordance with the user manual It does not cover events and conditions outside of Sprue Safety Products Ltd s control such as Acts of God fire severe weath...

Страница 12: ......

Отзывы: