Maintenance and inspection

  WARNING

Be sure to turn off the air and power before performing maintenance. Failure to follow this may cause an accident or malfunction.
The tip of the electrode needle is pointed. Be very careful when cleaning it.

If water, oil or paint, etc., adheres to the product, wipe it off with a cloth, etc. In particular, if it adheres to the electrode needle or the inside of nozzle, wipe it off 

immediately

.

If the electrode needle becomes dirty, the static elimination performance will deteriorate. When the static elimination effect gradually decreases, remove the nozzle 

and clean the electrode needle and the area around the electrode needle with a cloth or brush.

Clean the needle regularly every two weeks. Failure to follow this may result in a failure of the product because the ability to eliminate static electricity will not be 

fully performed.

Clean the inside of the nozzle if dirt accumulates.
The electrode needle and the wave motion air nozzle are consumable parts. They deteriorate in performance due to wear, etc. after long-term use, and must be 

replaced periodically. Replace the electrode needle every 20,000 hours of use, and the wave motion air nozzle every 2,000 hours of use as a guide.

  How to clean the electrode needle and its surroundings

Rotate the nozzle and remove it from the main body. Clean the electrode needle and its surroundings inside the main unit (gun) with a cotton swab soaked with 

alcohol (IPA). If dirt adheres to the tip of the electrode needle, the static elimination effect will be reduced. After cleaning, attach the nozzle firmly.

  How to clean the wave motion air nozzle

Wipe off any dust or dirt adhering to the cone with a cloth or cotton swab. If it is very dirty, remove the wave motion air nozzle from the main unit (gun) and wash 

it with water. If washed with water, dry it thoroughly before attaching it to the main unit. Set the tightening torque for replacement to 1.5 to 2.0N cm. If the torque 
is not correct, the screws of the main unit may be damaged.

  How to replace the electrode needle

The electrode needle a consumable part and must be replaced. When replacing the electrode needle, be sure to use the screwdriver for the electrode needle (sold 

separately) in combination, and set the tightening torque to 15 to 2.0 N-cm at the time of replacement. If the torque is not correct, the screws of the main unit may 
be damaged.

  Other inspections

Area/part to be Inspected

Details of inspection

Inspection method

Inspection frequency

Treatment of the issue found

Power input cable

Is there any disconnection?

Visual inspection

Everyday

Replacing Parts

AC adapter

Is the outlet disconnected?

Visual inspection

Everyday

Re-plug into an outlet

■ 

Trouble shooting

Phenomenon

Main causes

Remedy

Power does not turn on

Power is not turned on.

Check if the AC adapter is connected to the power supply and the main unit.

Air does not come out

Air is not supplied

Open the main air valve

Static electricity

elimination performance 

has deteriorated

Dirty or worn electrode needle

Clean the electrode needle and the area around the needle, or replace the electrode needle.

Red LED is ON *5

Dirty or worn electrode needle

Clean the electrode needle and the area around the needle, or replace the electrode needle.

Electrode short-circuited

Check if there is no conductive material near the electrode needle.

Nozzle contacts the ground body

Do not bring the nozzle into contact with the ground body.

Nozzle looseness

Tighten the nozzle securely to the gun body.

*5. If Red LED is lit and the remedy does not solve the problem, the high-voltage transformer may be damaged or the PCB may be malfunctioning, repair is required.

■ 

List of spare parts

Part name

Code No.

Wave motion air nozzle unit

90003190

Five pieces of replacement 

electrode needles

90003200

Electrode needle screwdriver

90003210

Power cable

90003220

AC adapter

90003230

*Replacement electrode needle (90003200) is sold as a set of 5 pieces.

Electrode needle screwdriver (90003210)

Содержание SER-24PA

Страница 1: ...r be seriously injured if protective measures are not implemented WARNING Indicates that if the warning is neglected it may result in death or serious injury CAUTION Indicates that if the caution is n...

Страница 2: ...ozone concentration in the enclosed space may increase resulting in the development of chronological bronchitis etc A high voltage is applied to the electrode needle Do not put any conductive objects...

Страница 3: ...15 65 unless no condensation Indicators Green Power supply normal Red Decrease in output power Ozone generation 0 04 ppm or less 200 mm from the spout air pressure 0 3MPa Ion balance Within 30V Materi...

Страница 4: ...unit or the nozzles will become dirty lowering the electrostatic elimination performance and causing deterioration of the main unit Secure a work space when installing this product Also secure enough...

Страница 5: ...fficient the nozzle may loosen due to the vibration of the wave motion air nozzle which is dangerous if it comes off Connect the power input cable of the main unit gun to the AC adapter Connect the AC...

Страница 6: ...htening torque to 1 5 to 2 0N cm If the torque is not correct the thread of the gun body side may be damaged Operation 1 Open the main valve of the air equipment installed by the customer and supply a...

Страница 7: ...tightening torque for replacement to 1 5 to 2 0N cm If the torque is not correct the screws of the main unit may be damaged How to replace the electrode needle The electrode needle a consumable part a...

Страница 8: ...8 3176 Shinyoshida cho Kohoku Ku Yokohama 223 8501 Japan No T1090 00...

Отзывы: