7
■
Maintenance and inspection
WARNING
Be sure to turn off the air and power before performing maintenance. Failure to follow this may cause an accident or malfunction.
The tip of the electrode needle is pointed. Be very careful when cleaning it.
If water, oil or paint, etc., adheres to the product, wipe it off with a cloth, etc. In particular, if it adheres to the electrode needle or the inside of nozzle, wipe it off
immediately
.
If the electrode needle becomes dirty, the static elimination performance will deteriorate. When the static elimination effect gradually decreases, remove the nozzle
and clean the electrode needle and the area around the electrode needle with a cloth or brush.
Clean the needle regularly every two weeks. Failure to follow this may result in a failure of the product because the ability to eliminate static electricity will not be
fully performed.
Clean the inside of the nozzle if dirt accumulates.
The electrode needle and the wave motion air nozzle are consumable parts. They deteriorate in performance due to wear, etc. after long-term use, and must be
replaced periodically. Replace the electrode needle every 20,000 hours of use, and the wave motion air nozzle every 2,000 hours of use as a guide.
How to clean the electrode needle and its surroundings
Rotate the nozzle and remove it from the main body. Clean the electrode needle and its surroundings inside the main unit (gun) with a cotton swab soaked with
alcohol (IPA). If dirt adheres to the tip of the electrode needle, the static elimination effect will be reduced. After cleaning, attach the nozzle firmly.
How to clean the wave motion air nozzle
Wipe off any dust or dirt adhering to the cone with a cloth or cotton swab. If it is very dirty, remove the wave motion air nozzle from the main unit (gun) and wash
it with water. If washed with water, dry it thoroughly before attaching it to the main unit. Set the tightening torque for replacement to 1.5 to 2.0N cm. If the torque
is not correct, the screws of the main unit may be damaged.
How to replace the electrode needle
The electrode needle a consumable part and must be replaced. When replacing the electrode needle, be sure to use the screwdriver for the electrode needle (sold
separately) in combination, and set the tightening torque to 15 to 2.0 N-cm at the time of replacement. If the torque is not correct, the screws of the main unit may
be damaged.
Other inspections
Area/part to be Inspected
Details of inspection
Inspection method
Inspection frequency
Treatment of the issue found
Power input cable
Is there any disconnection?
Visual inspection
Everyday
Replacing Parts
AC adapter
Is the outlet disconnected?
Visual inspection
Everyday
Re-plug into an outlet
■
Trouble shooting
Phenomenon
Main causes
Remedy
Power does not turn on
Power is not turned on.
Check if the AC adapter is connected to the power supply and the main unit.
Air does not come out
Air is not supplied
Open the main air valve
Static electricity
elimination performance
has deteriorated
Dirty or worn electrode needle
Clean the electrode needle and the area around the needle, or replace the electrode needle.
Red LED is ON *5
Dirty or worn electrode needle
Clean the electrode needle and the area around the needle, or replace the electrode needle.
Electrode short-circuited
Check if there is no conductive material near the electrode needle.
Nozzle contacts the ground body
Do not bring the nozzle into contact with the ground body.
Nozzle looseness
Tighten the nozzle securely to the gun body.
*5. If Red LED is lit and the remedy does not solve the problem, the high-voltage transformer may be damaged or the PCB may be malfunctioning, repair is required.
■
List of spare parts
Part name
Code No.
Wave motion air nozzle unit
90003190
Five pieces of replacement
electrode needles
90003200
Electrode needle screwdriver
90003210
Power cable
90003220
AC adapter
90003230
*Replacement electrode needle (90003200) is sold as a set of 5 pieces.
Electrode needle screwdriver (90003210)