6
■
Operation
WARNING
Do not use the product with the nozzle pointing toward the animal, human body, especially face or eyes. Failure to follow this may result in bodily injury. Also,
use protective goggles, masks to prevent dust from hitting a face or getting into eyes due to bounceback. There is a danger of loss of eyesight due to dust, etc.
It is recommended to wear ear plugs for health and safety. The noise level may be 80dB (A) or more depending on the operating conditions and the working
environment.
Be sure to supply air when using this product. If the power is turned on without supplying air, the internal ozone concentration will increase due to the electric
discharge, which may adversely affect the equipment and the environment.
Never make the nozzle at the gun tip, which is connected to the internal circuit touch any conductor or live cable. It may cause electric shocks or malfunction.
CAUTION
Piezoelectric ceramics are built into the air gun.
Avoid dropping or impacting. It will be the cause of the failure.
Do not use other than the genuine nozzle.
Otherwise, the neutralization (static electricity elimination) effect may
not be obtained, or damage may result.
When installing the wave motion air nozzle, set the tightening torque
to 1.5 to 2.0N cm.
If the torque is not correct, the thread of the gun body side may be
damaged
Operation
1)
Open the main valve of the air equipment (installed by the customer) and supply air with the specified pressure to the main body.
2)
Hold the main unit with hand, point the nozzle tip toward the workpiece (object charged with static electricity to be processed), and firmly grasp the lever of the
gun (main unit) until the main unit indicator lamp lights. Ionized air is blown out from the nozzle, static electricity of charged objects placed in the air flow is
neutralized and eliminated, and dust adhering to charged objects is removed.
Normal air is blown out from the wave motion air nozzle to remove the adhered dust.
3)
The air flow balance between static electricity elimination and dust removal can be adjusted by turning the adjustment screw for ionized air flow rate
(see "Specifications").
Turn the adjustment screw clockwise to reduce the ionized air flow and increase the shock wave wind pressure.
Turn the adjustment screw counterclockwise to increase the ionized air flow rate and reduce the shock wave wind pressure.
4)
Loosen the hand grip and return the lever of the gun (main unit) to shut off the ionized air.
5)
When stopping the operation of product, stop supplying power to the AC adapter and stop the main valve of air.
WARNING
Do not drop or apply impact.
!
!
Hazardous voltage.
φ
43
波動型ノズル
Wave motion air nozzle