Operation

WARNING

Do not use the product with the nozzle pointing toward the animal, human body, especially face or eyes. Failure to follow this may result in bodily injury. Also, 

use protective goggles, masks to prevent dust from hitting a face or getting into eyes due to bounceback. There is a danger of loss of eyesight due to dust, etc.

It is recommended to wear ear plugs for health and safety. The noise level may be 80dB (A) or more depending on the operating conditions and the working 

environment.

Be sure to supply air when using this product. If the power is turned on without supplying air, the internal ozone concentration will increase due to the electric 

discharge, which may adversely affect the equipment and the environment.

Never make the nozzle at the gun tip, which is connected to the internal circuit touch any conductor or live cable. It may cause electric shocks or malfunction.

CAUTION

Piezoelectric ceramics are built into the air gun.

Avoid dropping or impacting. It will be the cause of the failure.

Do not use other than the genuine nozzle.

Otherwise, the neutralization (static electricity elimination) effect may 
not be obtained, or damage may result.

When installing the wave motion air nozzle, set the tightening torque

  to 1.5 to 2.0N cm.

If the torque is not correct, the thread of the gun body side may be 

  damaged

  Operation

1)

Open the main valve of the air equipment (installed by the customer) and supply air with the specified pressure to the main body.

2)

Hold the main unit with hand, point the nozzle tip toward the workpiece (object charged with static electricity to be processed), and firmly grasp the lever of the 
gun (main unit) until the main unit indicator lamp lights. Ionized air is blown out from the nozzle, static electricity of charged objects placed in the air flow is 
neutralized and eliminated, and dust adhering to charged objects is removed. 
Normal air is blown out from the wave motion air nozzle to remove the adhered dust.

3)

The air flow balance between static electricity elimination and dust removal can be adjusted by turning the adjustment screw for ionized air flow rate 
(see "Specifications"). 
Turn the adjustment screw clockwise to reduce the ionized air flow and increase the shock wave wind pressure. 
Turn the adjustment screw counterclockwise to increase the ionized air flow rate and reduce the shock wave wind pressure.

4)

Loosen the hand grip and return the lever of the gun (main unit) to shut off the ionized air.

5)

When stopping the operation of product, stop supplying power to the AC adapter and stop the main valve of air.

WARNING

Do not drop or apply impact.

!

!

Hazardous voltage.

φ

43

波動型ノズル

Wave motion air nozzle

Содержание SER-24PA

Страница 1: ...r be seriously injured if protective measures are not implemented WARNING Indicates that if the warning is neglected it may result in death or serious injury CAUTION Indicates that if the caution is n...

Страница 2: ...ozone concentration in the enclosed space may increase resulting in the development of chronological bronchitis etc A high voltage is applied to the electrode needle Do not put any conductive objects...

Страница 3: ...15 65 unless no condensation Indicators Green Power supply normal Red Decrease in output power Ozone generation 0 04 ppm or less 200 mm from the spout air pressure 0 3MPa Ion balance Within 30V Materi...

Страница 4: ...unit or the nozzles will become dirty lowering the electrostatic elimination performance and causing deterioration of the main unit Secure a work space when installing this product Also secure enough...

Страница 5: ...fficient the nozzle may loosen due to the vibration of the wave motion air nozzle which is dangerous if it comes off Connect the power input cable of the main unit gun to the AC adapter Connect the AC...

Страница 6: ...htening torque to 1 5 to 2 0N cm If the torque is not correct the thread of the gun body side may be damaged Operation 1 Open the main valve of the air equipment installed by the customer and supply a...

Страница 7: ...tightening torque for replacement to 1 5 to 2 0N cm If the torque is not correct the screws of the main unit may be damaged How to replace the electrode needle The electrode needle a consumable part a...

Страница 8: ...8 3176 Shinyoshida cho Kohoku Ku Yokohama 223 8501 Japan No T1090 00...

Отзывы: