Anest Iwata SER-24PA Скачать руководство пользователя страница 1

電源入力ケーブル(3m)

ACアダプタ

AC100V〜240Vへ

エアー入力(φ6)

エアチューブ(φ6)

本体

エア源へ

Instruction Manual 

DEIONIZING AIR BLOW GUN

SER-24PA 

More than 2,000V AC high voltage is dealt with the product, therefore, be sure to read this manual before using the product to fully understand the functions 
of this unit. 
Keep the manual for future use. 

■ 

Residual risk 

Residual risk map requiring protective measures by the product user 
Model: "

 DEIONIZING AIR BLOW GUN

SER-24PA

Residual risks are classified and described according to the definition below.

DANGER 

Indicates that a person is likely to die or be seriously injured if protective measures are not implemented. 

WARNING 

Indicates that if the warning is neglected, it may result in death or serious injury.

CAUTION 

Indicates that if the caution is neglected, it may result in injury or property damage.

The symbols and numbers of the parts shown in the figure correspond to those listed in the "List of Residual Risks" of this product. For details on each residual risk, 
refer to "Residual Risk List".

Residual risk where parts on the equipment 
are not identified 

DANGER 

Warning 

No.2,No.3,No.6 

Caution 

L

oc

ati

on 

B

DANGER 

Warning 

No.5 

Note 

L

oc

ati

on 

A

DANGER 

Warning 

No.4

Note 

L

oc

ati

on 

C

DANGER 

Warning 

No.1 

Caution 

Optional 

Air tube 

Gun body 

Power input cable (3M)

AC Adapter

Air inlet

Содержание SER-24PA

Страница 1: ...r be seriously injured if protective measures are not implemented WARNING Indicates that if the warning is neglected it may result in death or serious injury CAUTION Indicates that if the caution is n...

Страница 2: ...ozone concentration in the enclosed space may increase resulting in the development of chronological bronchitis etc A high voltage is applied to the electrode needle Do not put any conductive objects...

Страница 3: ...15 65 unless no condensation Indicators Green Power supply normal Red Decrease in output power Ozone generation 0 04 ppm or less 200 mm from the spout air pressure 0 3MPa Ion balance Within 30V Materi...

Страница 4: ...unit or the nozzles will become dirty lowering the electrostatic elimination performance and causing deterioration of the main unit Secure a work space when installing this product Also secure enough...

Страница 5: ...fficient the nozzle may loosen due to the vibration of the wave motion air nozzle which is dangerous if it comes off Connect the power input cable of the main unit gun to the AC adapter Connect the AC...

Страница 6: ...htening torque to 1 5 to 2 0N cm If the torque is not correct the thread of the gun body side may be damaged Operation 1 Open the main valve of the air equipment installed by the customer and supply a...

Страница 7: ...tightening torque for replacement to 1 5 to 2 0N cm If the torque is not correct the screws of the main unit may be damaged How to replace the electrode needle The electrode needle a consumable part a...

Страница 8: ...8 3176 Shinyoshida cho Kohoku Ku Yokohama 223 8501 Japan No T1090 00...