- 8 -
●
Inspection
Where to inspect
When to replace parts
1.
Each hole passage of cap and nozzle
*Replace if damaged or deformed.
2.
Packing or o rings
*Replace if damaged or worn out.
3.
Seat section between nozzle and
needle for leakage
*Replace if there is still leakage even after you clean nozzle and needle.
If you replace nozzle or needle
only, first match up nozzle and needle to see if there is any leakage.
*When replacing nozzle, use exclusive tool and gradually tighten. Use of
other tools can cause breakage of thread or incomplete centering.
4.
Tip of needle
*Replace if bent or broken.
You cannot repair a bent needle. Replace it with a new one immediately.
Damaged needle can cause adverse atomization and damage to tip of
nozzle or inner diameter.
●
Problems and remedies
Problems
Place of
Problem
Where to check
Causes
Remedies
R1
R2
R3
R4
Paint leaks
tip of brush
fluid nozzle~
fluid needle
dirt, damage, wear on seat
○
○
Bend of needle tip
○
insufficient nozzle tightening
○
Needle and nozzle are not locked
completely
After loosening needle
locking screw and
removing knob of the
valve, touch needle with
nozzle lightly and put
the knob and tighten
needle locking screw.
need
~
needle
chucking nut
loose needle chucking nut
○
Paint does not
come out
tip of air brush
fluid nozzle
clogged
○
needle chucking nut
insufficient tightening
○
needle cap
nozzle
cap
dirty needle and nozzle cap
○
Needle
Clogged
○
●
Causes and remedies of incomplete spray patterns
Pattern
Causes
Remedies
Skipping
Paint sticks to tip of needle
Clean tip of needle.
Air enters screw section between nozzle and body
Remove nozzle, clean screw Section
and retighten.
Tip of nozzle is set back from tip of nozzle cap
Tighten nozzle and cap.
Spattering
Paint sticks to tip of nozzle, needle or needle cap
Clean nozzle, needle or needle cap
Bent tip of needle, break or damage to tip of nozzle Replace parts.
Nozzle is clogged.
Clean nozzle.
Atomizing air pressure is too low.
Increase air pressure.
Paint viscosity is too high.
Reduce its viscosity.
Please contact your local Anest Iwata agent for inquiries.