1. Safety precaution 

 

 

WARNING

 

 

 

Fire and explosion   

 

1. Spark and open flames are strictly prohibited.                                                                                                                         

Paints can be highly flammable and can cause fire.                                                                                                     

Avoid any ignition sources such as smoking, open flames, electrical goods, etc.     

2. Be sure to stop pump, reduce fluid pressure down to 0 pressure and securely apply safety 

lock of airless pole gun before you fit or remove nozzle tip. 

Emission  of  paint  or  solvent  during  operation  can  cause  great  danger.

  

3. Securely ground airless pole gun by using fluid hose with built-in ground wire. 

 

Ground wire 

:

 Less than 

M

Ω

. Check the earth stability periodically. 

Securely ground pump, airless pole gun, workpiece and containers containing paint or solvent. Be sure to use 

fluid hose with built-in ground wire to have continuous grounding between pump and airless pole gun. Use 

conductive container containing paint or solvent. Insufficient grounding will cause explosion or fire by spark of 

electricit. 

If not, insufficient grounding can cause fire and explosion due to static electric sparking. 

4. Never use the following HALGOGENATED HYDROCARBON SOLVENTS                                                                                 

which can cause cracks or dissolution on gun body (aluminum) by chemical reaction.                                                 

<unsuitable solvents>

methyl chloride, dichloromethane, 1.2-dichloroethane,carbon tetrachloride, 

  trichloroethylene, 1.1.1-trichloroethane. 

 

   

Be sure that all fluids and solvents are compatible with gun parts.    We are ready to supply a material list used in the product

 

 

 

Improper use of equipment 

 

1. Never point airless pole gun toward people or animal. 

Never  pull  trigger  of  gun  when  human  body  or  finger  come  near  tip  of  nozzle  tip.  If  done,  it  can 

cause inflammation of eyes and skin or bodily injury. 

If you feel any abnormality during operation, consult 

with a medical doctor immediately. 

2. Never exceed maximum operating pressure and

 

maximum operating Temperature. 

Usage at more than max. operating pressure can cause explosion of airless pole gun resulting in great danger. 

3. Be sure to release fluid pressures before cleaning, disassembling or servicing. 

If not, remaining pressure can cause bodily injury due to improper operation or scattering cleaning liquid. 

In order to release pressure, first stop supply of fluid and thinner to airless pole gun. 

 

 

 

Protection of human body 

 

1

Use in a well-ventilated site by using spray booth. 

If not, poor ventilation can cause organic solvent poisoning and catch fire.

 

If you feel any 

abnormality during operation, consult with a medical doctor immediately. 

2

Always wear protective gear 

safety glasses, mask, gloves

If not, cleaning liquid, etc., can cause inflammation of eyes and skin. 

If you feel something wrong with eyes or skin, immediately see a doctor. 

3. Wear earplugs if necessary. 

Noise level can exceed 

85dB

(A), depending on operating conditions and painting site.

 

4. Be sure to stop pump, reduce fluid pressure down to 0 pressure and securely apply 

safety lock of airless pole gun before you fit or remove nozzle tip. 

Emission  of  paint  or  solvent  during  operation  can  cause  great  danger.

  

5

Never try to stop leaks by hand, when paint leaks.   

In that case, stop pump immediately and reduce paint pressure down to 0 pressure. 

High pressure paint emitted through small hole can pierce an iron plate and can cause severe injury 

since paint can enter human body directly through eye, mouth or skin. It is very dangerous. If you 

feel any abnormality or receive any injury, consult with a medical doctor immediately 

6

If operators pull the trigger many times during operation, it may cause carpal tunnel syndrome. 

Be sure to take a rest if you feel tired. 

7

If  operators  feel  the  pulsations  in  the  coating  material  flow  long  time  during  operation,  it  may  cause  carpal  tunnel 

syndrome. 

Be sure to take a rest if you feel  tired.  Or  damping  of  the  pulsations  in  the  coating  material  flow  from  paint  pump  by,  for 

instance, the use of damping elements on the inlet connection(s) of the equipment or the use of pulsation damping hoses 

supplying the equipment.

 

 

Burst of fluid hose

 

1. Never use cracked, damaged, bent or crushed fluid hose.                                                                 

 

High pressure paint emitted at small hole can pierce an iron plate and cause great danger. 

2. Never bend fluid hose with a radius of less than permitted bend radius.

   

 

Contact the shop who sold the hose to you, or us, about permitted bend radius. Never put heavy things on it in order not to damage the 

hose. If done, hose can explode causing great danger.

 

 

 

Содержание AP-96-05

Страница 1: ...120...

Страница 2: ......

Страница 3: ......

Страница 4: ...cm cm MPa cm ml sec cm...

Страница 5: ...3 4 1 3 5 1 3 6 1 3 7 1 3 8 1 4 1 1 4 2 1 4 3 1 4 4 1 5 1 6 1 1 6 2 1 6 3 1 6 4 1 7 1 8 1 9 1 10 1 11 2 12 1 12 1 1 12 2 1 12 3 8 12 4 1 12 5 1 12 6 1 12 7 1 12 8 1 12 9 1 13 1 14 1 15 1 16 1 17 1 18...

Страница 6: ...rranty is valid only in Japan 14 11 18 3 4 16 16 12 6 11 5 3 3 12 7 12 6 18 12 1 3 4 kgf cm2 12 8 0800 100 1926 0120 917 144 9 00 12 00 13 00 17 00 http www anest iwata co jp No 1076 08 No 03296224 22...

Страница 7: ...40PSI Tested with water Air Fluid Measuring point 1m backwards from gun m height Main specifications Model Max operating pressure MPa bar PSI Pole length m Use Fluid output ml min Fluid hose connectio...

Страница 8: ...per operation or scattering cleaning liquid In order to release pressure first stop supply of fluid and thinner to airless pole gun Protection of human body 1 Use in a well ventilated site by using sp...

Страница 9: ...isconnected during operation hazardous hose movement and paint ejection will cause severe bodily injury 5 If something goes wrong immediately stop operation and find the cause Do not use again until y...

Страница 10: ...free pattern tip each tip optional Refer to 4 and prepare nozzle tip separately Be sure to stop pump reduce fluid pressure down to 0 pressure and securely apply safety lock of airless pole gun before...

Страница 11: ...t except ALG 73 Remove No 12 handle from gun body Remove and clean No 11 filter set 4 Selection of nozzle tip according to kind of paint H I N T Numbering system Pattern width 25 cm at 30cm spray dist...

Страница 12: ...g used Replace with new tip or proper sized tip Paint does not stop smoothly Pump pressure is too high Reduce paint pressure down to 25 MPa 250bar 3 626PSI Paint leaks from the gun tip Paint sticks to...

Страница 13: ...3 6 nozzle seat spring 1 12 6 needle packing 2 3 7 O ring 1 12 7 needle packing seat 1 3 8 spring seat 1 12 8 needle packing holder 1 4 1 fluid pipe set 1 for 05 12 9 screw 1 4 2 fluid pipe set 1 for...

Страница 14: ...14 Manual No 1076 08 Code No 03296224 3176 Shinyoshida cho Kohoku Ku Yokohama 223 8501 Japan...

Отзывы: