- 8 -
1. Safety precaution
WARNING
Fire and explosion
1. Spark and open flames are strictly prohibited.
Paints can be highly flammable and can cause fire.
Avoid any ignition sources such as smoking, open flames, electrical goods, etc.
2. Be sure to stop pump, reduce fluid pressure down to 0 pressure and securely apply safety
lock of airless pole gun before you fit or remove nozzle tip.
Emission of paint or solvent during operation can cause great danger.
3. Securely ground airless pole gun by using fluid hose with built-in ground wire.
Ground wire
:
Less than
1
M
Ω
. Check the earth stability periodically.
Securely ground pump, airless pole gun, workpiece and containers containing paint or solvent. Be sure to use
fluid hose with built-in ground wire to have continuous grounding between pump and airless pole gun. Use
conductive container containing paint or solvent. Insufficient grounding will cause explosion or fire by spark of
electricit.
If not, insufficient grounding can cause fire and explosion due to static electric sparking.
4. Never use the following HALGOGENATED HYDROCARBON SOLVENTS
which can cause cracks or dissolution on gun body (aluminum) by chemical reaction.
<unsuitable solvents>
:
methyl chloride, dichloromethane, 1.2-dichloroethane,carbon tetrachloride,
trichloroethylene, 1.1.1-trichloroethane.
(
Be sure that all fluids and solvents are compatible with gun parts. We are ready to supply a material list used in the product
)
Improper use of equipment
1. Never point airless pole gun toward people or animal.
Never pull trigger of gun when human body or finger come near tip of nozzle tip. If done, it can
cause inflammation of eyes and skin or bodily injury.
If you feel any abnormality during operation, consult
with a medical doctor immediately.
2. Never exceed maximum operating pressure and
maximum operating Temperature.
Usage at more than max. operating pressure can cause explosion of airless pole gun resulting in great danger.
3. Be sure to release fluid pressures before cleaning, disassembling or servicing.
If not, remaining pressure can cause bodily injury due to improper operation or scattering cleaning liquid.
In order to release pressure, first stop supply of fluid and thinner to airless pole gun.
Protection of human body
1
.
Use in a well-ventilated site by using spray booth.
If not, poor ventilation can cause organic solvent poisoning and catch fire.
If you feel any
abnormality during operation, consult with a medical doctor immediately.
2
.
Always wear protective gear
(
safety glasses, mask, gloves
)
.
If not, cleaning liquid, etc., can cause inflammation of eyes and skin.
If you feel something wrong with eyes or skin, immediately see a doctor.
3. Wear earplugs if necessary.
Noise level can exceed
85dB
(A), depending on operating conditions and painting site.
4. Be sure to stop pump, reduce fluid pressure down to 0 pressure and securely apply
safety lock of airless pole gun before you fit or remove nozzle tip.
Emission of paint or solvent during operation can cause great danger.
5
.
Never try to stop leaks by hand, when paint leaks.
In that case, stop pump immediately and reduce paint pressure down to 0 pressure.
High pressure paint emitted through small hole can pierce an iron plate and can cause severe injury
since paint can enter human body directly through eye, mouth or skin. It is very dangerous. If you
feel any abnormality or receive any injury, consult with a medical doctor immediately
6
.
If operators pull the trigger many times during operation, it may cause carpal tunnel syndrome.
Be sure to take a rest if you feel tired.
7
.
If operators feel the pulsations in the coating material flow long time during operation, it may cause carpal tunnel
syndrome.
Be sure to take a rest if you feel tired. Or damping of the pulsations in the coating material flow from paint pump by, for
instance, the use of damping elements on the inlet connection(s) of the equipment or the use of pulsation damping hoses
supplying the equipment.
Burst of fluid hose
1. Never use cracked, damaged, bent or crushed fluid hose.
High pressure paint emitted at small hole can pierce an iron plate and cause great danger.
2. Never bend fluid hose with a radius of less than permitted bend radius.
Contact the shop who sold the hose to you, or us, about permitted bend radius. Never put heavy things on it in order not to damage the
hose. If done, hose can explode causing great danger.