Anest Iwata AP-96-05 Скачать руководство пользователя страница 7

- 7 - 

 

 

 
 
 
 

Airless  Pole  Gun

   

 

 

 

     

  Important 

 

 
 
 
 

 
 

Be  sure  to  observe  warnings  and  cautions  in  this  instruction  manual. 

If  not,  it  can  cause  paint  ejection  and  serious  bodily  injury  by  drawing  organic  solvent. 

Be  sure  to  observe  following 

  marked  items  which  are  especially  important.

 

WARNING 

Indicates  a  potentially  hazardous  situation  which,  if  not  avoided,  may  result  in  serious  injury  or  loss  of  lif

e. 

CAUTION 

Indicates  a  potentially  hazardous  situation  which,  if  not  avoided,  may  result  in  minor  or  moderate  injury  or 

property damage. 

  Important 

 

Indicates  notes  which  we  ask  you  to  observe.    The  safety  precautions  in  this  instruction  manual  are  the 

minimum necessary conditions.    Follow national and local regulations regarding fire prevention, electricity and 

safety as well as your own company regulations. 

 

Important specifications                                                                                                                                                                                                         

 

Max. Pressure 

25MPa

    /   

250

 

bar

  /   

3600

 

PSI

 

 

Max. Temperature 

 

Noise level 

62.9  dB

 

(A)

 

 

Atmosphere

 

 

5℃~40℃

 

Spray condition 

Used  nozzle  tip.;  NT-3005 
Fluid  pressure.  ;  10  MPa  /  100bar  /  1440PSI

 

Tested with water. 

 

Air

Fluid 

5℃~43℃

 

 

 

 

 

Measuring point 

1m backwards from gun,

1.6

  m    height 

 

 

 

 

 

Main specifications 

                                                                                                                                                                                                                                                                                                   

 

Model

 

Max.operating  pressure 

MPa 

(bar  /  PSI) 

Pole 

length 

Use 

Fluid  output 

ml/min 

Fluid  hose 

connection 

Fiter 

mesh 

Mass 

kg(lbs) 

AP-96-05 

25 

(250  /  3600) 

0.5 

General 

Refer  to 

4.Selection  of  nozzle  tip   

according  to  kind  of  paint 

G  1/4 

120  mesh 

(built  in) 

1.0  (2.2) 

AP-96-10 

1.0 

1.25  (2.8) 

AP-96-15 

1.5 

  1.5  (3.3) 

AP-96-20 

2.0 

 

1.75  (3.9) 

 

 
 
 

   

This  Anest-iwata  airless  pole  gun  kit  complies  to 

ATEX regulations 94/9/EC,   

Protection level 

 

2 G X

Suitable for use in Zones 1 and 2. 

X marking

  :

 

Any  static  electricity  discharge  from  the  airless

 

pole gun is to be diverted to the grounded 

the conductive fluid hose as stipulated. 

 

AP-96-05/10/15/20 

 

INSTRUCTION MANUAL 

   

 

This manual contains IMPORTANT WARNINGS and INSTRUCTIONS. 

  Equipment in this manual is exclusively for painting purposes. 

  Do not use for other purposes. 

  The operator shall be fully conversant with the requirements stated in this 

  instruction manual including important warnings, cautions and operation and 

  correct handling. 

  Read and understand the instruction manual, before use and retain for 

  reference.   

Содержание AP-96-05

Страница 1: ...120...

Страница 2: ......

Страница 3: ......

Страница 4: ...cm cm MPa cm ml sec cm...

Страница 5: ...3 4 1 3 5 1 3 6 1 3 7 1 3 8 1 4 1 1 4 2 1 4 3 1 4 4 1 5 1 6 1 1 6 2 1 6 3 1 6 4 1 7 1 8 1 9 1 10 1 11 2 12 1 12 1 1 12 2 1 12 3 8 12 4 1 12 5 1 12 6 1 12 7 1 12 8 1 12 9 1 13 1 14 1 15 1 16 1 17 1 18...

Страница 6: ...rranty is valid only in Japan 14 11 18 3 4 16 16 12 6 11 5 3 3 12 7 12 6 18 12 1 3 4 kgf cm2 12 8 0800 100 1926 0120 917 144 9 00 12 00 13 00 17 00 http www anest iwata co jp No 1076 08 No 03296224 22...

Страница 7: ...40PSI Tested with water Air Fluid Measuring point 1m backwards from gun m height Main specifications Model Max operating pressure MPa bar PSI Pole length m Use Fluid output ml min Fluid hose connectio...

Страница 8: ...per operation or scattering cleaning liquid In order to release pressure first stop supply of fluid and thinner to airless pole gun Protection of human body 1 Use in a well ventilated site by using sp...

Страница 9: ...isconnected during operation hazardous hose movement and paint ejection will cause severe bodily injury 5 If something goes wrong immediately stop operation and find the cause Do not use again until y...

Страница 10: ...free pattern tip each tip optional Refer to 4 and prepare nozzle tip separately Be sure to stop pump reduce fluid pressure down to 0 pressure and securely apply safety lock of airless pole gun before...

Страница 11: ...t except ALG 73 Remove No 12 handle from gun body Remove and clean No 11 filter set 4 Selection of nozzle tip according to kind of paint H I N T Numbering system Pattern width 25 cm at 30cm spray dist...

Страница 12: ...g used Replace with new tip or proper sized tip Paint does not stop smoothly Pump pressure is too high Reduce paint pressure down to 25 MPa 250bar 3 626PSI Paint leaks from the gun tip Paint sticks to...

Страница 13: ...3 6 nozzle seat spring 1 12 6 needle packing 2 3 7 O ring 1 12 7 needle packing seat 1 3 8 spring seat 1 12 8 needle packing holder 1 4 1 fluid pipe set 1 for 05 12 9 screw 1 4 2 fluid pipe set 1 for...

Страница 14: ...14 Manual No 1076 08 Code No 03296224 3176 Shinyoshida cho Kohoku Ku Yokohama 223 8501 Japan...

Отзывы: