2.2
CLASSICflo Balanced connections & technical data
Natural Gas
Andrews Models
Unit
RSC 9/145
RSC 9/180
Input (gross)
kW
11.1
11.1
Input (net)
kW
10.0
10.0
Output (gross)
kW
8.88
8.88
Efficiency (Net CV)
%
88.80
88.80
Efficiency (Gross. thermal)
%
80
80
Gas Flow Rate
m
3
/hr
0.93
0.93
Nominal Gas Inlet Pressure
mbar
18 - 25
18 - 25
Main Burner Pressure
mbar
12.0
12.0
NOx
ppm
8
12
NOx
mg/kWh
15
21
CO2 Flue Gas
%
7.50 - 9.00
7.50 - 9.00
Noise Level
dBA
40
40
Recovery Rate (through 50°C rise)
l/h
152
152
Recovery Rate (through 56°C rise)
l/h
136
136
Minimum Flow Rate
l/s
N/A
N/A
Water Content
Litres
145
179
Weight Empty
kg
71
79
Weight Full
kg
216
258
Shipping Weight
kg
80
89
Storage Losses
kWh/l/day
N/A
N/A
Inlet/Outlet Connections
Inch BSP
3/4”
3/4”
Return Connection
Inch BSP
3/4”
3/4”
Gas Connection
Inch BSP
1/2”
1/2”
Condensate Connection
mm
N/A
N/A
Twin Pipe Conventional
mm
N/A
N/A
Flue Diameter (concentric)
mm
80 - 125
80 - 125
Ionisation Current (min)
A
0.8
0.8
Ionisation Current (max)
A
30
30
Electrical Requirements
V
230
230
Power Consumption
W
120
120
Fuse Rating
A
5
5
Maximum Flue Gas Temperature
°C
300
300
Flue Static Pressure
mbar
N/A
N/A
Waterside Pressure Loss
kPa
N/A
N/A
Maximum Outlet Temperature
°C
80
80
Maximum Working Pressure
Bar
10.3
10.3
Minimum Working Pressure
Bar
1.0
1.0
Diameter
mm
559
559
Water Heater Height
mm
1276
1505
Height to Vent Connection
mm
1613
1842
7
Issue 4 21042018