background image

31

Combustion unit and gas route LWHC56,WHC56

140

143

116

072

113

102

106

108

072

072

072

072

105

171

172

175

175

142

136

176

142

107

104

127

135

135

126

100

077

101

131

134

132

174

174

114

076

118

117

125

110

Содержание Fastflo WHC56

Страница 1: ...WHC56 Internal INSTALLATION AND SERVICE MANUAL Andrews Built to perform Please read and understand these instructions before commencing installation and leave this manual with the customer for future reference Part number E890 SBA8198 3 ...

Страница 2: ......

Страница 3: ...sed by ignoring this symbol Possibility of serious injury or even death as well as possibility of fire when the product is misused by ignoring this symbol Possibility of bodily injury or damage to property when the product is misused by ignoring this symbol The appliance must be installed in accordance with the Gas Safety Installation and Use Regulations and the rules in force in the country of in...

Страница 4: ...lation Q ty Shape Part Tapping Screw 1 Part Shape Q ty 5 Installation Manual this document 1 Owner s Guide System Controller 1 Remote Controller 1 Horizontal Flue Terminal 1 Short Horizontal Flue Terminal 1 Long 1 Vertical Flue Terminal 1 1 1 Special Adapter For intake pipe 1 1 Attach the seal ring included with the Flue Terminal optional accessories to the groove of exhaust side of equipment secu...

Страница 5: ...56 140W G20 20mbar 55 8kW CONDENSING CONDENSING Freeze Preventive Heater 55 8kW 2 98kW 2 98kW 54 0kW 54 0kW 3 20kW 3 20kW GB IE GB IE G31 30 37mbar 140W 170W 170W LWHC56 3P 10 0mbar 2 7mbar 12 9mbar 3 0mbar ...

Страница 6: ...ices System Diagram Insulate the hot water piping to prevent heat loss Insulate and apply heating materials to the cold water supply piping to prevent heat loss and freezing of pipes when exposed to excessively cold temperatures G Quick Connect Cord Remote Controller Cord Gas Supply Piping Cold Water Supply Hot Water Remote Controller Terminal Block Cord Connector Cord Connector Leave enough clear...

Страница 7: ...th a solar pre heater can lead to unpredictable output temperatures and possibly scalding If absolutely necessary use mixing valves to ensure output temperatures do not get to scalding levels Do not use a solar pre heater with the quick connect multi system Checkup Check the fixing brackets and the flue pipe yearly for damage or wear Replace if necessary 4 Before Installation Caution Precautions o...

Страница 8: ... bathroom it may be dam aged or a fire may be caused Warning Caution Consult with the customer concerning the location of installation Avoid places where fires are common such as those where petrol benzene and adhesives are handled or places in which corrosive gases ammonia chlorine sulfur ethylene compounds acids are present This may cause incomplete combustion or failures Locate the flue termina...

Страница 9: ...between the kitchen fan and stove If oily fumes or a large amount of steam are present in the installation location take measures to prevent the fumes and steam from entering in the equipment Avoid installation in places where dust or debris will accumulate Dust may causing the performance of the fan motor to drop and incomplete combustion to occur as a result Install in a location where the exhau...

Страница 10: ... applied to an area where an effective shield makes a clearance of 600mm or more in front of the exhaust outlet Check Illustration Caution If possible leave 200mm or more on either side of the unit to facilitate inspection If possible leave 600mm or more in front of the unit to facilitate main tenance and service if necessary Securing of space for repair inspection 600mm or more 200mm or more Outd...

Страница 11: ...nd hang the unit by the upper wall mounting bracket 3 Determine the positions for the remaining four screws two for the top bracket and two for the bottom and remove the unit The weight of the device will be applied to the wall If the strength of the wall is not suffi cient reinforcement must be done to prevent the transfer of vibration Do not drop or apply unnecessary force to the device when ins...

Страница 12: ... that the drain trap unit is filled with water 700ml Intake Exhaust 1 Fill the drain trap unit by pouring approx 700ml of water into the exhaust accessory on the top of the appliance as illustrated below Or if the vent pipe has already been installed 2 After installing the drain pipe make sure that the area around the appliance is well ventilated open a window or a door if necessary Then operate t...

Страница 13: ...300mm or more in a plain view regardless of the vertical clearance Flue Terminal Flue Terminal 300mm or more 300mm or more In the case the discharge direction of the exhaust is to the side as shown in the diagram below do not select the supply exhaust tube top Incomplete combustion caused by short cycling of exhaust gas may occur as a result except terminal guard 8 Flue Pipe Installation Flue Term...

Страница 14: ...way from the appliance Push pipes fully into the sockets on top of the boiler whilst also fitting the flue duct prepared as above b Measure and cut next pair of the air flue pipes c Prepare pipe support brackets as required before engaging pipes with the socket of preced ing pipes or bends d Push pipes together as before taking care not to dislodge seals When cutting and fitting the flue pipes on ...

Страница 15: ...0 150 150 315 125 Special adapter Pitched roof Flat roof Heater to flue adapter Air and flue adapter Maximum length 1745 Maximum length 12000 with 1 x 90 bend Maximum length 7000 with 4 x 90 bends Maximum length 860 Air and flue adapter HORIZONTAL FLUE TERMINAL LONG VERTICAL FLUE TERMINAL HORIZONTAL FLUE TERMINAL SHORT suit wall thickness Standard length cut to Maximum length 560 ...

Страница 16: ...he outdoors Flue Precautions Use 100mm diameter exhaust pipe Maximum flue length 4 elbow 90 degree 7m exhaust pipe Flue Terminal Maximum flue length 12m Minimum flue length 1 elbow 90 degree Flue Terminal Exceeding the maximum flue length is danger ous and may result in bad combustion Maximum 90 degree bends not to exceed 4 Maximum length must be reduced by 2000mm for each 90 bend used Maximum len...

Страница 17: ...iameter exhaust pipe Maximum flue length 4 elbow 90 degree 7m exhaust pipe Flue Terminal Maximum flue length 12m Minimum flue length 1 elbow 90 degree Flue Terminal Exceeding the maximum flue length is danger ous and may result in bad combustion Maximum 90 degree bends not to exceed 4 Maximum length must be reduced by 2000mm for each 90 bend used Maximum length must be reduced by 1000mm for each 4...

Страница 18: ...nstall the exhaust pipe at the hidden part install the access hole for checking the full length of exhaust pipe with eye If the partition wall goes right through the hidden part be sure to install the access hole near the wall Suggested inspection openings When the intake exhaust pipes pass through an enclosed space Ceiling Sloping up toward flue terminal Exhaust pipe ...

Страница 19: ... be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 35 mbar The Appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 35 mbar The appliance and its gas connections must be l...

Страница 20: ...to keep the piping simple Avoid piping in which an air holdup can occur Use approved piping materials If installing the unit on a roof If the unit is installed on a roof to supply water to the levels below make sure that the water pressure supplied to the unit does not drop below 2000 mbar It may be necessary to install a pump system to ensure that the water pressure is maintained at this level Ch...

Страница 21: ...o the electrical supply must be through one common isolator and must be fused 10 Amp maximum Isolation should be by a double pole switched fused spur box with a minimum gap of 3 mm for both poles The fused spur box should be readily accessible and preferably adjacent to the appliance It should be identified as to its use Caution Label all wires prior to disconnection when servicing controls Wiring...

Страница 22: ...it Keep the remote controller cord away from the freeze prevention heaters in the unit Tie the redundant cord outside the water heater Do not put the extra length inside the equipment The remote controller cord can be extended up to 100m with Remote controller cord Use a Y type terminal with a resin sleeve Without the sleeve the copper wire may corrode and cause problems Be sure to hand tighten wh...

Страница 23: ...12 Commissioning The installer should test operate the unit explain to the customer how to use the unit and give the owner this manual before leaving the installation Preparation 1 Ensure all lines are purged flushed of debris prior to connection to appliance 2 Open the shut off valve on the water supply check that water passes through the valve and close the valve 3 Open the gas supply valve turn...

Страница 24: ... when placed into contact with water Keep the drain pipe length to a minimum Install the pipe with a decline when horizontally pulling the pipe in the middle The end of the drain pipe must be released in to the air Be sure the pipe is not submerged in water In addition take measures to prevent clogging of the pipe After performing piping check to make sure drain water is properly drained In the ca...

Страница 25: ...3 4 UPPER WALL MOUNT BRACKETS LOWER WALL MOUNT BRACKETS EXHAUST PIPE CONNECTION OPERATION LAMP 4 13 WATER DRAIN VALVE CONDENSATE DRAIN WATER FILTER HOT WATER OUTLET WATER DRAIN VALVE OVER WATER PRESSURE RELIEF VALVE WIRING THROUGHWAY WATER DRAIN VALVE COLD WATER INLET HOT WATER OUTLET R3 4 CONDENSATE DRAIN R1 2 WIRING THROUGHWAY POWER CORD COLD WATER INLET R3 4 VIEW FROM TOP HEIGHT OF EACH FITTING...

Страница 26: ...ARY CIRCULATION PUMP RELAY 7 AC100V AC230V 10A FUSE NEUTRAL O SV O W 4 GY BL 3 5 BK 1 W 2 W 0 10 BL 7 8 6 R 3 2 1 4 BL R DU 11 12 13 GY GY O BK BK Q2 SV SV Q1 SV GAS VALVE UNIT 3 1 2 4 Manifold Gas Pressure Decrease Button Manifold Gas Pressure Increase Button Maximum Manifold Pressure Set Button Minimum Manifold Pressure Set Button BL CN102 W Y O R W CN63 WW W CN75 CN70 W Y R Y BL EXTERNAL POWER ...

Страница 27: ...r 2 Position the holes diameter 6 mm X depth 25 30 mm to secure the remote controller for the kitchen and knock in all the wall anchors Next secure it using oval headed wood screws 3 Replace the decorative cover Oval headed wood screws The screws must be tightened manually and the remote controller secured properly without rattling Main remote controller body 15 Remote Controller Installation Manu...

Страница 28: ...e boiler should be isolated from the electrical supply and water supply and the gas supply should be turned off at the gas service cock All routine servicing requirements can be achieved by the removal of the front panel only Remove the four screws on the front panel and lift off For access inside the appliances screwdriver can be used To remove chassis front Unless stated otherwise any part remov...

Страница 29: ...igure and pull the bypass servo B B A 3 Unscrew two fixing screws A and B in the right figure and remove the transformers 2 How to remove the board 1 Unscrew two screws A and B that fix the board and the earth screw C and remove the board A B C B A ...

Страница 30: ... two fixing screws of mounting plate for current leakage safety device in advance 1 Remove the quick fastener A in the right figure and slide the gas pipe B upward 2 Unscrew four screws that fix the manifold and pull out the manifold SET A B ...

Страница 31: ...tfitting LWHC56 WHC56 18 Servicing parts lists 003 002 002 003 001 005 073 072 044 045 071 A 031 B 032 033 007 077 017 016 072 034 072 046 078 034 072 028 072 042 076 072 075 043 072 072 029 027 021 C H 041 I 037 036 ...

Страница 32: ... 7287909 2 036 Wiring coupling 2 EHK EHKA014 1 037 Grommet ELE ELEA031 1 041 Mounting plate for terminal block DZT DZTA006 1 042 Current leakage safety device 240 EJS EJSJ022 1 043 Power supply cord ELE ELEJ006 1 044 Transformer EPJ EPJJ061 1 045 Transformer cover EJS EJSA021 1 046 Conduit 90 2 CCP CCPJ028 1 071 Cross recessed truss type3 EVERTIGHT tapping screw with PW 4X12 072 Cross recessed rou...

Страница 33: ...ombustion unit and gas route LWHC56 WHC56 140 143 116 072 113 102 106 108 072 072 072 072 105 171 172 175 175 142 136 176 142 107 104 127 135 135 126 100 077 101 131 134 132 174 174 114 076 118 117 125 110 ...

Страница 34: ...D7463 1 3P Gas mech manifold 23 ELV SET AS SKD7462 126 Manifold seal packing top ELV ELVL003 1 127 Manifold seal packing bottom ELV ELVL007 1 131 Solenoid SO9L EBT SET V SBP7501 2 132 Solenoid S16 CRU SET V SBB7213 1 134 Gas mech harness ELV ELVJ018 1 135 O ring JASO 2030 type 1 SAA6044 3 136 Quick fastener 16B 6340407 1 140 Gas fitting 20A SET EPJ EPJE021 1 142 O ring P18 2110903 2 143 Manifold p...

Страница 35: ...BACK THERMAL FUSE LEFT SIDE FASTENER FASTENER 403 407 406 410 410 411 408 171 418 424 419 481 417 429 413 446 417 432 435 412 432 435 445 431 484 435 432 432 435 418 440 444 441 416 437 443 405 176 404 483 G F E 410 D 077 461 442 400 438 Thermal fuse rounding procedure 410 411 403 400 407 405 461 ...

Страница 36: ...432 434 433 482 421 419 482 420 418 414 F G D C 472 072 072 473 474 466 432 475 452 466 432 442 463 466 465 457 432 442 477 459 464 441 077 E 464 455 416 458 477 456 451 467 453 460 441 416 468 176 467 460 462 404 478 477 479 B 072 469 454 176 485 480 485 487 459 476 489 471 072 486 488 ...

Страница 37: ...lter cover DTJ DTJD006 1 427 Water filter SUS EGB EGBD032 1 428 QMF safety valve A S SAA2811 1 429 Conduit 86 DZT DZTJ008 1 431 O ring P22C 7573308 1 432 O ring P16C 3223302 9 433 O ring P12 5C 3359808 1 434 Quick fastener 12 7 6340202 1 435 Quick fastener 16A 6340300 5 437 Sensor fastener CRU CRUD055 1 438 Bypass pipe ENJ ENJD005 1 440 Hot water thermistor 300 BWC BWCD096 1 441 Hot water resistan...

Страница 38: ... EMUJ001 1 477 Hose clamp NO 35 SAD6670 3 478 Remaining flame safety device 80 ENJ ENJH001 1 479 Thermostat BVU BVUH002 1 480 Neutralizer packing ENJ ENJL007 1 481 Cross recessed round head P TIGHT screw 4X10 482 Cross recessed round head P TIGHT screw 4X10 483 Cross straight recessed round head collar type3 S TIGHT tapping screw 4X8 484 Cross recessed round head machine screw M4X8 485 Cross reces...

Страница 39: ...56 WHC56 Remote controller Kitchen remote controller RC 7508M Special part Special part no Special part Owner s guide 888 Installation manual 889 Electronic control unit Attached set 700 701 715 705 076 A 703 805 H 075 751 752 786 788 787 072 I 789 785 804 716 For 3P ...

Страница 40: ...13 786 785 Oar plug 6X25 787 Cross recessed flat head screw M4X35 788 Cross recessed flat head wood screw All screw 4 1X20 789 Cross recessed bind machine screw M3 5X5 800 GQC3252WZFF AD packing set V SKF7138 804 Screw SET W SAB2753 805 Cross recessed round head type 1 tapping screw 5X35 888 Owner s guide GQC3252WZFFAD SBA8089 889 Installation manual GQ C3252WZFFAD SBA8198 1 1 1 1 1 716 gas type s...

Страница 41: ...ntion Device Overheat Preven tion Device Freezing Prevention Device Fan Rotation Detector Anchoring Screws Performance Item Model Name Type Ignition Minimum Pressure for Maximum flow Minimum Flow Rate Dimensions Weight Water Holding Capacity Accessories Installation Air Supply Exhaust Connection Sizes Power Supply Materials Water Inlet Hot Water Outlet Gas Inlet Condensate Drain Supply Consumption...

Страница 42: ...power level indoors L WA dB 57 57 57 57 57 57 57 57 Daily fuel consumption Q fuel kWh 30 452 30 452 30 332 30 332 27 73 27 46 33 57 33 01 Emissions of nitrogen oxides NO X mg kWh 70 70 70 70 52 52 60 60 Weekly fuel consumption with smart controls Qfuel week sm kWh Weekly electricity consumption with smart controls Qelec week sm kWh Weekly fuel consumption without smart controls Qfuel week kWh 213 ...

Страница 43: ......

Страница 44: ...wsWH 500403 Register now to activate your warranty www andrewswaterheaters co uk register a warranty Please make sure you attach proof of purchase for your warranty to be monitored All descriptions and illustrations provided in this document have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the Conditions of Sale which are avail...

Отзывы: