3
Installation
3.1
Introduction
The law requires that installation is carried out by a
properly qualified person
Install in accordance with current British Standard Code of
Practice 342 part 2 and British Standards 5440, 5546, 6644,
6700, 6798 and 6891.
3.2
Location
The location chosen for the heater must permit the provision of a
satisfactory flue and an adequate air supply.
The heater must not be installed in a room which contains
a bath or a shower and must not be installed in a bedroom
or bedsitting room.
A suitable clearance should be left around the heater for fitting
and servicing purposes. The above clearances given on page 7
are recommended for ease of servicing. They can be reduced if
necessary but a clearance of 610mm must be left in front of
heater for access to the burner and controls. The flue baffle
clearance should also be maintained if possible to avoid
servicing problems.
The floor on which the heater is installed must be flat, level and
of sufficient strength to withstand the weight of the heater when
filled with water, and should satisfy the requirements of the Local
Authority & Building Regulations.
Any combustible material adjacent to the heater must be so
placed or shielded as to ensure that its temperature does not
exceed 65°C.
3.3
Assembling the draught diverter
The draught diverter must be assembled with the legs provided.
Attach the legs to the draught diverter with the nuts and bolts
provided.
Fit the draught diverter (1) as shown in Fig.1 to the water
heater using the screws provided. For Standard Range fit the
draught diverter to the top of the water heater using the
location holes
In some cases, it may be necessary to drill the fixing holes in
the top cover to fit the draught diverter to the water heater.
By using the draught diverter as a template, position
carefully over the flueway and mark the hole positions to be
drilled 4mm
Fit the adaptor socket (2) and seal into the draught diverter
as shown and attached flue spillage thermostat (3) to the
draught diverter with the bolts provided
2
1
Outlet
Intlet
Fig.1
3
11
Содержание 10/105
Страница 4: ...9 Appendix 57 9 1 Dismantling Disposal and Recycling 57 Copyright 57 ...
Страница 21: ...3 11 Wiring Diagram Fig 10 21 ...