Error code
Definition of code
Cause of problem and actions taken to correct
32
Lower sensor
readings faulty
Resistance of lower sensor out of operating range. Check
continuity of wire harness to lower sensor, and if O.K., replace
lower sensor.
57
Flame rod shorted
to ground
Pilot flame sensor rod is shorted to ground. Check to see if flame
sensor wire has bare spots touching metal parts of if flame sensor
rod is touching the pilot shield or other metal parts. Replace pilot if
flame sense wire is damaged or flame rod is bent.
58
AC line frequency
error – Signal too noisy
or frequency incorrect
Check line voltage frequency to the water heater. Determine if there
are wide fluctuations. Call an electrician if the problem persists. The
water heater should be on a separate line.
59
Line voltage too low
or high
Check line voltage to the water heater. Determine cause of low or
high voltage. Call an electrician or your utility. The water heater
should be on a separate line.
61
DC output voltage
unstable
Check line voltage to the water heater for erratic readings. Also
check wiring to make sure there are no shorts. If power supply and
wiring is O.K., replace control board.
62
Maximum number of
retries detected
Pilot is either not lighting or not staying lit during the ignition cycle.
Check inlet gas pressure for minimum pressure on rating label. Is
pilot electrode sparking? Check gas valve wire harness for broken
wires or shorts. If 24 volts is present between PV and PV/MV
terminals at the gas valve, replace gas valve. Check for voltage
output to the yellow and red gas valve wires on the control board
pins. If during the ignition trial period, there is no voltage present at
the control board pin terminal for the red and yellow wires leading
to the gas valve, then replace the control board. Replace pilot if
wires are damaged or electrode is damaged.
63
Maximum number of
ignition recycles
detected
Pilot flame is lost during run cycle, then reestablished on ignition
cycle. Check inlet gas pressure. Is gas pressure dropping below
the minimum operating pressure on the rating label after the main
gas valve opens? Is the gas pipe size to the water heater
adequate? Check the pilot shield position and condition of the
burners. Clean or replace as needed. Check the pilot flame and
observe the microamp output on the run cycle. Check the pilot
tubing to the pilot and replace if crimped or damaged. Replace pilot
if wires, flame sensor, or electrode is damaged.
64
Electronics Failure
Replace control board.
65
High Water
Temperature (Over
93°C)
Water temperature in tank has exceeded 93°C. Check lower
sensor. Make sure sensor is fully inserted into the well (clip on
sensor wire secures sensor in place). Check lower and upper
(where used) sensor readings. If not within specifications, replace
sensor. If sensor and wire harnesses check O.K., replace control
board.
49
Содержание 10/105
Страница 4: ...9 Appendix 57 9 1 Dismantling Disposal and Recycling 57 Copyright 57 ...
Страница 21: ...3 11 Wiring Diagram Fig 10 21 ...
Страница 51: ...8 Parts List 8 Parts List 8 1 General Assembly Fig 70 51 ...
Страница 52: ...Introduction 1 52 ...
Страница 53: ...Introduction 1 53 ...
Страница 54: ...Parts List 8 8 2 Control Box Assembly 54 ...
Страница 59: ......