4. Commissioning
Manual
MF0145AXA.doc
Manual for ION-M17P/19P Advanced
Page 23
4.2.4. Grounding
(Earthing)
Grounding must be carried out. Connect an earth-bonding cable to the grounding
connection provided at the outside of the Remote Unit (see
section
4.2.3
Connections
). Do not use the grounding connection to connect external devices.
figure 4-6 Grounding bolt (left) and schematic view (right)
After loosening the hex nut, connect the earth-bonding cable between the two
washers as illustrated in the above. Then, fasten all parts again with the hex nut.
Note:
Ground of a second unit (for example RU + EU) has to be connected to
the same equipotential bonding terminal as the Remote Unit. Use bonding
cables of the same length, as short as possible and with a large wire cross
section. Follow local electrical code practices.