![ANDI WMA 7612 L Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/andi/wma-7612-l/wma-7612-l_disassembly_2941867013.webp)
36- DOOR LOCK WIRE AND OPENING MECHANISM
•
Remove top plate and front panel.
•
Remove the clamp securing the door switch cable outer sleeve.
•
Pull downwards to release the outer sleeve of the wire.
•
Release wire and unhook inner wire from door switch.
•
Release the plastic snaps on the switch and pull free.
37- HEATER
•
Remove the rear panel.
•
Heater cables are disconnected. ( figure 15)
•
Loosen the heater M6 bolt and the heater is released from the tub (
When re-mounting, the heater should be secured by the heater fixture
clip in the tub ).
Figure 15
38- THERMOSTAT BULP AND ITS SEALING
•
Remove the rear panel.
•
Pull out the thermostat bulp/NTC from the tub.
•
Pull out the thermostat rubber sealing from the tub ( when remounting
the thermostat rubber sealing, ensure a water tight seal in the tub).
39- INTERFERENCE SUPPRESSOR
•
Remove top lid.
•
Disconnect interference suppressor
cables.
•
Remove the two screws in the plastic box behind the machine that
secure the terminal group to the cabinet.
•
Disconnect the interference supplier by loosening M8 nut.
40- UPPER COUNTER WEIGHT
•
Remove the top lid.
•
Remove the upper counter weight fixture screws and pull off the counter
weight.