Anderson Greenwood 5200 series Скачать руководство пользователя страница 16

16

F

1.5 x 2

150# - 600#

10131340

1.5 x 2.5

900# - 2500#

10131341

G

1.5 x 2/3

150# - 600#

10131342

1.5 x 2.5/3, 2 x 3

900# - 2500#

10131344

H

1.5/2 x 3

150# - 600#

10131346

900# - 1500#

10131347

J

2 x 3, 2 x 4, 2.5 x 4, 3 x4

150# - 600#

10131351

2 x 4

900# (WC6)

10131352

2 x 4

900# (WCB)

10131353

2.5 x 4

900#

10131352

3 x 4

900#

10131353

2/3 x 4

1500#

10131353

K

2.5/3 x 4

150# - 600#

10131358

900#

10131359

L

3 x 4, 3 x 6, 4 x 6

150# - 600#

10131363

3 x 6

900#

10131364

4 x 6

900#

10131366

M

4 x 6

150# - 600#

10131367

900#

10131368

N

4 x 6

150# - 600#

10131367

P

4 x 6

150# - 600#

10131370

Q

6 x 8

150# - 600#

11114194

r

6 x 8, 6 x 10

150# - 600#

11114197

T

8 x 10

150# - 600#

11114198

The set pressure range is 15 psig to 6250 psig. Model numbering is per below.

example:

52

4

7

10

J

23

/s1

pilot series

52

  Series 5200

Main valve lift

4

 

Full lift, APi orifice

Main valve piston type

7

 

Metal seat

Inlet flange rating, AnsI

05

 150#

14

 900#

10

 300#

16

 1500#

12

 600#

18

 2500#

orifice designation

letter

  APi equivalent

Inlet x outlet, inches
Main valve materials

/s

  WCB/WCC body, SS Trim (up to 800°F [427°C])

/s3

  WC6 body, SS Trim (800°F to 1000°F [538°C])

/spl

 Special

Anderson Greenwood

 SerieS 5200 POSrV

InstallatIon and MaIntenance InstructIons

Neither emerson, emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. 
responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.

Anderson Greenwood is a mark owned by one of the companies in the emerson Automation Solutions business unit of emerson electric Co. emerson Automation 
Solutions, emerson and the emerson logo are trademarks and service marks of emerson electric Co. All other marks are the property of their respective owners.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be 
construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by 
our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without 
notice.

emerson.com/FinalControl

9 soFT Goods repAIr KITs

9.1 Pilot repair kit:

Part number: 11044661

9.2 Main valve repair kits:

orifice

size

Inlet flange rating

part number

Содержание Greenwood 5200 series

Страница 1: ...truct the convection cooling process that keeps the main valve dome filled with condensate Refer to Anderson Greenwood Crosby Procedures 05 9040 352 VCIOM 06043 Installation and Start up Instructions...

Страница 2: ...main valve parts description and location Remove the pilot valve B condensate trap E bracket 16 sense ring 20 if installed associated tubing C and fittings D from the main valve Loosen the body drain...

Страница 3: ...POSRV Installation and Maintenance Instructions Remote sense assembly Item Description A Main valve B Pilot valve C Tubing D Tube fittings E Condensate trap 20 Sense ring optional Figure 1 Type 5247...

Страница 4: ...ginal condition Never lap the disc insert against the nozzle Lap each part separately against a cast iron lapping block of the proper size These blocks hold the lapping compound in their surface pores...

Страница 5: ...tion shown by dotted line Lapping block to be squared up Bottom rough surface do not use Lapping block resurfacing plate Lapping block Lapping blocks Lapping blocks are made of a special grade of anne...

Страница 6: ...906 2 487 3 2 493 3 3L4 150 thru 300 2 028 2 2 264 2 392 5 045 1 562 3 681 3 3 689 4 3L6 600 thru 900 2 028 2 2 264 2 392 6 201 1 562 3 681 3 3 689 4 4L6 150 thru 600 2 028 2 2 264 2 392 5 263 1 562 3...

Страница 7: ...sket 2 3 10 Lubricate cap stud 15 threads with pure Nickel Never Seez or equivalent and then install into the body 1 until they tighten against bottom of the body threaded hole There should be at leas...

Страница 8: ...haust seat retainer 19 Spring bonnet 34 Hex nut 5 Exhaust seat stem 20 Bonnet ring 35 Lift lever cap screw 6 Exhaust nozzle 21 Bonnet ring screw 36 Stem seal 7 Exhaust washer 22 Spring 37 Exhaust seat...

Страница 9: ...ond lapping compound or equal to the inlet seat s conical surface Hold the inlet nozzle in one hand and lightly lap the inlet seat with the inlet nozzle by spinning the inlet seat onto the inlet nozzl...

Страница 10: ...G 160 oil or equivalent on the internal threads of the bonnet and the threads of the pressure adjustment screw 25 Screw the adjustment screw into the bonnet until it contacts the top spring washer Thr...

Страница 11: ...s Condensate Condensate Condensate Condensate trap Pilot exhaust backflow check valve Field test connection Field test indicator O ring Ball Fitting Body Body Body Seats Seats Flow washer Shuttle Shut...

Страница 12: ...s of supply pressure Orifice Dome pressure A Reseat pressure B 6 2 Set pressure pilot only The pilot can be pre set and checked for leakage using air on a test set up similar to that shown in Figure 1...

Страница 13: ...steam 7 2 Set pressure check Slowly increase pressure to the valve inlet until the first audible discharge is detected This is set pressure Adjust set pressure as required to meet the performance req...

Страница 14: ...00 20 68 3 of set pressure 300 20 68 and 1000 68 95 10 psig 0 69 barg 1000 68 95 1 of set pressure 7 5 1 2 ASME BPVC Section VIII Applications Set Pressure psig barg Tolerance 70 4 83 2 psig 0 14 barg...

Страница 15: ...ent valve C and remove flexible hose from field test fitting 8 Pilot set pressure field test procedure 8 1 General The set pressure of valves equipped with the field test accessory can be checked with...

Страница 16: ...0 POSRV Installation and Maintenance Instructions Neither Emerson Emerson Automation Solutions nor any of their affiliated entities assumes responsibility for the selection use or maintenance of any p...

Отзывы: