SAFETY INSTRUCTIONS

 WARNING

1. 

120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing. Leave power 
disconnected until installation/service is completed.

2. 

Dropping may cause personal injury or equipment damage. Handle with care and follow installation instructions.

 CAUTION

1. 

Read all instructions before beginning installation.

2. 

Improper installation may cause property damage or injury. Read instructions before installation, service or maintenance.

3. 

Do not use in pool applications. Pool chemicals can damage the dehumidifier.

4. 

Do not use solvents or cleaners on or near the circuit board. Chemicals can damage circuit board components.

5. 

Wait 24 hours before running the unit if it was not shipped or stored in the upright position

6. 

Do not use dehumidification to prevent window condensation in the winter. To address window condensation, use ventilation to lower 
indoor humidity in the winter.

DEHUMIDIFIER CONTROL

ON/OFF

 BUTTON 

USED TO TURN 

DEHUMIDIFIER ON 

AND OFF

UP/DOWN

 

BUTTONS USED TO 

CHANGE HUMIDITY 

SETTING

MODE

 BUTTON USED 

FOR OPTIONAL 

VENTILATION FEATURE

INLET

FILTER ACCESS DOOR

DRAIN

POWER 

SWITCH

OUTLET

90-1952

READ AND SAVE THESE INSTRUCTIONS

Model A95F Dehumidifier

Installation and Operating Instructions

1

Содержание A95F

Страница 1: ...tions Pool chemicals can damage the dehumidifier 4 Do not use solvents or cleaners on or near the circuit board Chemicals can damage circuit board components 5 Wait 24 hours before running the unit if...

Страница 2: ...PERATION 8 Using the Dehumidifier Control 8 Using the Model A77 Remote Control 8 TROUBLESHOOTING 9 Table 1 Diagnostic Codes 9 Table 2 Troubleshooting Guide 10 SERVICE PARTS 11 LIMITED WARRANTY 12 SPEC...

Страница 3: ...emoval of the side panel shown Allow sufficient space for service on this side of the unit Always install the dehumidifier in a condensate pan when locating in or over a finished space CLIP OFF PLASTI...

Страница 4: ...l surface is required to ensure proper drainage from the dehumidifier CONDENSATE PAN CONDENSATE PUMP AND FLOAT SWITCH A condensate pan is recommended when locating in or above a finished space or susp...

Страница 5: ...en to secure 4 Restore dehumidifier power There is a delay of three minutes after restoring power before the dehumidifier will respond to the control 5 Go to REMOTE CONTROL on page 6 to configure the...

Страница 6: ...r for the installed application Use the UP or DOWN buttons to select items and use MODE to switch to the next set up option To exit installer set up all options must be scrolled through using the MODE...

Страница 7: ...red the dehumidifier and all of the wired components will turn on and off during Installer Test Mode to demonstrate that all are properly operating Installer Test Mode lasts for four 4 minutes If the...

Страница 8: ...he setting the blowers turn off and the display returns to showing the RH setting 4 The dehumidifier will sample again after the number of minutes selected during the Air Sampling portion of the Syste...

Страница 9: ...sensor temperature while also displaying ON Scroll through these values and by using the UP DOWN arrow buttons 7 Record values and call Technical Support Cycle Power E5 High Temperature Thermistor Fai...

Страница 10: ...ty condensate pan If no float switch installed check that the jumper is installed at the float switch terminals on the control board Coil frosting defrost Lack of or reduced airflow Check dehumidifier...

Страница 11: ...6 Wire Harness Power Deh 5454 7 Sensor Low Temperature Deh 5455 8 Sensor High Temperature Deh 5456 No Part Description Part No 9 Capacitor 45MFD 370VAC 70pt 95pt Deh compressor 5458 10 Capacitor 12MFD...

Страница 12: ...LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BREA...

Отзывы: