User manual
Guangzhou Andea Electronics Technology Co., Ltd. 10/15
http://www.gzandea.com
③
Output format of block’s data:
A. Format as hex string.
B. Format as ASCII.
④
Output format of UID:
A. Format as hex string.
B. Format as LSB 3 bytes convert to integer string.
C. Format as LSB 4 bytes convert to integer string.
D. Format as compliant with Wiegand.
E. Format as compliant with Wiegand fix 8 bytes.
⑤
UID length: 0-8, 0 for unlimited length, output of a complete UID.
4) Parameter of reading block with ISO15693
Byte offset: the offset of the first byte to be read.
Byte count: the number of bytes to be read.
Note: The parameters listed here are commonly used parameter configurations.
For other parameter settings, please consult our technicians for configuration.
4.3.
Testing
4.3.1.
Multi-tags Inventory Testing
After entering the main interface of R-Tool test software, select "ISO Multi-Tag
Test" ,carry out the procedure as shown in the following figure
①
,
②
and
③
for tags
inventory test: