13
2.
Connect the two black wires
b
together using a UL listed wire connector.
3.
Connect the two neutral (white) wires
c
and the ground (green or bare) wire
d
(of the oven cable) using a UL listed wire connector.
4.
Connect the two red wires
g
together using a UL listed wire connector.
5.
Install junction box cover.
4-WIRE CONNECTION (UNGROUNDED NEUTRAL) - U.S.A. AND
CANADA
4-Wire Cable from Home Power Supply
IMPORTANT:
Use the 4-wire cable from home power supply in the U.S. where
local codes do not allow grounding through neutral, New Branch circuit
installations (1996 NEC), mobile homes and recreational vehicles, new construction
and in Canada.
1.
Disconnect power.
Ungrounded Neutral
i
b
c
d
g
f
e
h
a
a
Junction Box
b
Black Wires
c
Red Wires
d
Cable from Oven
e
UL listed or CSA
Approved Conduit
Connector
f
Ground (Green or
Bare) Wires
g
UL Listed Wire
Connector
h
Neutral (White) Wires
i
House Electrical Supply
2.
Connect the 2 black wires
b
together using a UL listed wire connector.
3.
Connect the 2 red wires
c
together using a UL listed wire connector.
4.
Untwist white wire from green (or bare) ground wire coming from the oven.
5.
Connect the 2 neutral (white) wires
h
together using a UL listed wire connector.
6.
Connect the ground (green or bare) wire
f
from the oven cable to the ground
(green or bare) wire (in the junction box) using a UL listed wire connector.
7.
Install junction box cover.
Installation Instructions