6.4.2.1
EtherCAT Configuration
EtherCAT configuration is usually performed using EtherCAT manager software. To assist with
configuration, an EtherCAT Slave Information (ESI) file is provided in the firmware bundle. This
.xml file describes the drive’s capabilities to the EtherCAT manager.
6.4.2.2
EtherCAT Connectors
PIU X3/X4 EtherCAT IN/OUT connectors.
Drive X17/X18 EtherCAT IN/OUT connectors.
6.4.2.3
EtherCAT Cables
To connect the AMD5x drive and PIU to other EtherCAT devices the following types of cables
must be used with Ethernet 8P8C modular connectors. They are commonly referred to as
“RJ45 shielded patch leads”.
Table 27: EtherCAT Cables
Cable
Name
Cable Shield
Pair Shielding
Cat 5e or Above
F/UTP
Foil
None
SF/UTP
Screen and Foil
None
TP = Twisted Pair
U = Unscreened pairs
F = Foil
S = Screened (Braid type)
Either straight or crossover cables may be used.
Refer
Cables for suitable cables
X3
EtherCAT IN
X4
EtherCAT OUT
X17
EtherCAT IN
X18
EtherCAT OUT