System Wiring Diagram for SolarMax
WARNING
This charger controller must be used with an external GFDI device as required by the Article 690 of the National
Electrical Code (NEC) for the installation location.
The simplified single-line drawing below shows the appropriate location and maximum amper- age capacity rating of
circuit breakers. Please note that all circuit protection devices must be installed inside UL/CSA recognized enclosures.
Follow all applicable electrical codes.
Wiring methods shall be in accordance with NEC, ANSI/NFPA 70.
Only use circuit protection equipment which is DC rated for the appropriate amperage capacity and DC voltage.
Wiring Your System
Wiring to and from the SolarMax must be sized and installed in accordance with your local electrical code. Installation
should be performed by a qualified electrician.
Connections to and from the SolarMax require sealed copped ring terminal lugs with 5/16” hole.