v.  NEVER smoke or allow a spark or flame in vicinity of battery or engine.
vi.  Be extra cautious to reduce risk of dropping a metal tool onto battery.  It might spark 

or short-circuit battery or other electrical part that may cause explosion.

vii.  Remove personal metal items such as rings, bracelets, necklaces, and watches 

when working with a lead-acid battery.  A lead-acid battery can produce a short-

circuit current high enough to weld a ring or the like to metal, causing a severe burn.

viii.  NEVER charge a frozen battery.
ix.  If necessary to remove battery from service, always remove grounded terminal from 

battery first.  Make sure all accessories are off, so as not to cause an arc.

x.  Be sure area around battery is well ventilated.
xi.  Clean battery terminals.  Be careful to keep corrosion from coming in contact with 

eyes.

xii.  Study all battery manufacturer’s specific precautions such as removing or not 

removing cell caps while charging and recommended rates of charge.

xiii.  Add distilled water in each cell until battery acid reaches level specified by battery 

manufacturer.  This helps purge excessive gas from cells.  Do not overfill.  For a 

battery without cell caps, carefully follow manufacturer’s recharging instructions.

3.  BATTERY CHARGER LOCATION

i.  Never place battery charger directly above battery; gases from battery will corrode 

and damage converter.

ii.  Never allow battery acid to drip on battery charger when reading gravity or filling 

battery.

4.  O/P CONNECTION PRECAUTIONS

 

Connect and disconnect all DC connections in a safe manner.

Analytic Systems does not recommend the use of the BCD180 Series Battery Chargers in life 

support applications where failure or malfunction of this product can be reasonably expected 

to cause failure of the life support device or to significantly affect its safety or effectiveness.  

Analytic Systems does not recommend the use of any of its products in direct patient care.

Examples of devices considered to be life support devices are neonatal oxygen analyzers, 

nerve stimulators (whether used for anaesthesia, pain relief, or other purposes), auto-trans-

fusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, 

haemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators 

for both adults and infants, anaesthesia ventilators, and infusion pumps as well as any other 

devices designated as “critical” by the U.S. FDA.

Содержание BCD180 Series

Страница 1: ...ES DC Battery Charger 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage Converters ...

Страница 2: ...Copyright 2005 2016 Analytic Systems Ware 1993 Ltd Revised May 17 2016 ...

Страница 3: ...S 1 WARNING RISK OF EXPLOSIVE GASSES i WORKING IN VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE SERVICING EQUIPMENT IN THE VICINITY OF THE BATTERY YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY ii To reduce risk of battery explosion follow these instructions ...

Страница 4: ...s from cells Do not overfill For a battery without cell caps carefully follow manufacturer s recharging instructions 3 BATTERY CHARGER LOCATION i Never place battery charger directly above battery gases from battery will corrode and damage converter ii Never allow battery acid to drip on battery charger when reading gravity or filling battery 4 O P CONNECTION PRECAUTIONS Connect and disconnect all...

Страница 5: ...d a wide operating temperature range This float charger will provide 15 amps maximum current at 12 volts or 7 5 amps at 24 volts nominal The charger maintains a constant output voltage When battery voltage reaches the charger voltage charge current is discontinued This unit can be used to power a passive load Specifications Input Voltages Nominal i p 32 48 72 Actual Vdc 20 45 40 65 65 100 Input Am...

Страница 6: ... Noise on Output 10 milli Volts Transient Response 1V for 50 Surge Output Amps 2 Efficiency 90 maximum output Temp Range 25 to 50 deg C maximum output Isolation 1500Vdc from Input to Case 500Vdc for 32V input 500Vdc from Output to Case Length 7 9 in 20 1 cm Width 6 0 in 15 2 cm Height 2 4 in 6 1 cm Clearance 1 Inch 2 5 cm all around Material Marine Grade Aluminium Finish Black Anodize Black Powder...

Страница 7: ...current rating of the unit The full load can be connected to one set of output terminals As soon as power is supplied to the input leads the output terminals become energized In passive load mode if the current demanded by the load connected to the unit exceeds the maximum output current rating the output voltage will drop to maintain the current at the maximum level If the fuse blows whenever it ...

Страница 8: ...8 This page intentionally left blank ...

Страница 9: ...ing will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed or altered in any way b Our invoice is unpaid c The defect is the result of misuse neglect improper installation environmental conditions non autho rized repair alteration or accident 7 No refund of t...

Страница 10: ... Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage Converters ...

Отзывы: