Sub MkIIP Oxygen & Carbon Dioxide Monitor 
User Manual - US Navy Version 

 

Document Ref

: AS2-802-14 - 

January 2016 

Page 20 

  

 

11  Warranty information 

 
We provide the following Warranties for the Sub MkIIP: 
 

 

 

A 3 month O2 sensor 
A 2 year CO2 bench 
A 1 year electronics warranty. 

 

 

 

In both cases the Warranty period runs from the date of our Invoice. 

 

 

 

We  warrant  that  the  equipment  will  be  free  from  defects  in  workmanship  and 
materials.  

 

 

 

The Warranty does not extend to and we will not be liable for defects caused by the 
effects  of  normal  wear  and  tear,  erosion,  corrosion,  fire,  explosion,  misuse,  use  in 
any context or application for which the equipment is not designed or recommended, 
or unauthorised modification. 

 

 

 

Following a valid Warranty claim in accordance with the above, the equipment, upon 
return  to  us,  would  be  repaired  or  replaced  without  cost  or  charge  but  in  our 
discretion we may elect instead to provide to you which ever is the lesser of the cost 
of  replacement  or  a  refund  of  net  purchase  price  paid  as  per  our  Invoice  on  initial 
purchase from us.   We shall have no  liability for losses, damages, costs  or delays 
whatsoever.  We shall have no liability for any incidental or consequential losses or 
damages.      All  express  or  implied  warranties  as  to  satisfactory  or  merchantable 
quality, fitness for a particular or general purpose or otherwise are excluded and no 
such Warranties are made or provided, save as set out in this Clause 7.  
 

 

In order to effectively notify a Warranty claim, the claim with all relevant information 
and documentation should be sent in writing to:  

 

 

 

Analox Limited  
15 Ellerbeck Court  
Stokesley Business Park  
Stokesley 
North Yorkshire 
TS9 5PT  
 
Or by e-mail to : 

[email protected]

 

Or by Fax to : +44 1642 713900 

 

 

 

We reserve the right to require from you proof of dispatch to us of the notification of 
Warranty claim by any of the above alternative means. 

 

 

 

The  equipment  should  not  be  sent  to  us  without  our  prior  written  authority.    All 
shipping  and  Insurance  costs  of  returned  equipment  are  to  be  born  by  you  and  at 
your risk.  All returned items must be properly and sufficiently packed.   

 

 
 
 
 
 
 
 

Содержание SA1 W75 SR 60 N 564

Страница 1: ...ck Court Stokesley Business Park North Yorkshire TS9 5PT UK T 44 0 1642 711400 F 44 0 1642 713900 W www analox net E info analox net Sub MkIIP Oxygen Carbon Dioxide Monitor User Manual US Navy Version...

Страница 2: ......

Страница 3: ...al power 100 240VAC 8 6 Calibration 9 6 1 Readout check 9 6 2 Use of calibration gas 10 7 Data logging 11 7 1 Installation of data logging software on a PC 11 7 2 Data logging program overview 13 7 3...

Страница 4: ...Sub MkIIP Oxygen Carbon Dioxide Monitor User Manual US Navy Version Document Ref AS2 802 14 January 2016 Page 2...

Страница 5: ...supply cable Part Number SAEP AS2 605 c User manual d Test certificates e Analox hyperbaric tested batteries x4 Part Number 2557 4625 Optional f Data output cable Part Number SAEP AS2 602 and softwar...

Страница 6: ...ch the standard instrument has only one operator control A single pushbutton controls backlights for each of the liquid crystal displays LCD and can also be used to reset the elapsed time The unit is...

Страница 7: ...the fuses in the external supply line or the battery circuit are not blown On powering up the instrument the sensor readings may take a short time to settle particularly the CO2 sensor which can take...

Страница 8: ...nstrument is operating from an external power supply The backlight is turned on by momentarily pressing the pushbutton on the front of the instrument The backlight will turn off automatically after a...

Страница 9: ...nt damage open the lid of the instrument using the two catches beside the handle b Undo the two Velcro retaining straps around the batteries c Ease each battery from its clips use one hand to grip the...

Страница 10: ...ypical current consumption figures are shown below Input Voltage V DC Load Current without backlight mA Load Current with backlight mA 9 0 160 315 12 0 105 340 24 0 55 290 40 0 37 270 5 2 External pow...

Страница 11: ...the right hand column as a guideline to the acceptable tolerance Also ensure that the SUB MkIIP is sampling the atmosphere from the same compartment as the CAMS To convert the CAMS Gas reading from u...

Страница 12: ...ed with the instrument will be required and should be fitted as shown in Figure 2 The longer free pipe should be connected to the outlet of a test gas bottle flow regulator The flow adaptors in the ch...

Страница 13: ...ensure all data from a DISSUB event is captured A cable is supplied to connect the SUB MkIIP to the serial port on a PC The cable is fitted with a 9 way female D type connector An adaptor will also b...

Страница 14: ...ED THE NEXT TIME YOU START THE PROGRAM 11 Always ensure that the Baud rate is set to 9600 to which it will default 12 Click on the Communicate with Instrument button You will see a message Please wait...

Страница 15: ...iable that you wish to view and a graph will be automatically generated This process will suspend logging you will therefore need to click on the Restart logging button on the Instrument Status page T...

Страница 16: ...be apparent Full Memory This option enables you to specify what the instrument should do when its data logging memory is full You may choose to Ignore newer data if for example you are conducting a s...

Страница 17: ...spreadsheet Therefore select an Excel compatible csv file CSV stands for a Comma Separated Variable file and is a format that most spreadsheet programs will recognize 8 Now select the folder and enter...

Страница 18: ...n the standard width of the cell Click on the A at the top of the column and then select Format Column and Autofit Selection Or simply drag the column separator between A and B to achieve the right wi...

Страница 19: ...calibration is required at least once every 12 months to replace the electrochemical oxygen sensor Where the instrument is used as a standby for use in emergencies replace the main batteries as detail...

Страница 20: ...effects Body Part Effect First Aid Procedures Skin Contact could result in a chemical burn Wash the affected part with a lot of water and remove contaminated clothing If stinging persists get medical...

Страница 21: ...cklight times out after 15 seconds when turned on Oxygen Sensors See Appendix on page 22 Analox 9100 9212 9HSUB oxygen sensor with microprocessor applied temperature compensation 2 3 year life at 21 S...

Страница 22: ...replacement or a refund of net purchase price paid as per our Invoice on initial purchase from us We shall have no liability for losses damages costs or delays whatsoever We shall have no liability f...

Страница 23: ...Version Document Ref AS2 802 14 January 2016 Page 21 12 Disposal According to WEEE regulation this electronic product can not be placed in household waste bins Please check local regulations for info...

Страница 24: ...yields the same partial pressure of oxygen as that present in the current environment SEV on the Sub MkIIP uses 1000mbara as its surface pressure for a point of reference For example 1 If the atmosph...

Страница 25: ......

Отзывы: