Table 11. Pin Definitions—Link Ports
Signal
Type
Term
Description
LxDATO3–0P
O
nc
Link Ports 3–0 Data 3–0 Transmit LVDS P
LxDATO3–0N
O
nc
Link Ports 3–0 Data 3–0 Transmit LVDS N
LxCLKOUTP
O
nc
Link Ports 3–0 Transmit Clock LVDS P
LxCLKOUTN
O
nc
Link Ports 3–0 Transmit Clock LVDS N
LxACKI
I (pd)
nc
Link Ports 3–0 Receive Acknowledge. Using this signal, the receiver indicates to the
transmitter that it may continue the transmission.
LxBCMPO
O (pu)
nc
Link Ports 3–0 Block Completion. When the transmission is executed using DMA, this
signal indicates to the receiver that the transmitted block is completed. The pull-up
resistor is present on L0BCMPO only. At reset, the L1BCMPO, L2BCMPO, and L3BCMPO
pins are strap pins. For more information, see
Table 16 on Page 20
.
LxDATI3–0P
I
V
DD_IO
Link Ports 3–0 Data 3–0 Receive LVDS P
LxDATI3–0N
I
V
DD_IO
Link Ports 3–0 Data 3–0 Receive LVDS N
LxCLKINP
I/A
V
DD_IO
Link Ports 3–0 Receive Clock LVDS P
LxCLKINN
I/A
V
DD_IO
Link Ports 3–0 Receive Clock LVDS N
LxACKO
O
nc
Link Ports 3–0 Transmit Acknowledge. Using this signal, the receiver indicates to the
transmitter that it may continue the transmission.
LxBCMPI
I (pd_l)
V
SS
Link Ports 3–0 Block Completion. When the reception is executed using DMA, this
signal indicates to the receiver that the transmitted block is completed.
I
= input;
A
= asynchronous;
O
= output;
OD
= open-drain output;
T
= three-state;
P
= power supply;
G
= ground;
pd
= internal pull-down
5 k
Ω
;
pu
= internal pull-up 5 k
Ω
;
pd_0
= internal pull-down 5 k
Ω
on DSP ID = 0;
pu_0
= internal pull-up 5 k
Ω
on DSP ID = 0;
pu_od_0
= internal
pull-up 500
Ω
on DSP ID = 0;
pd_m
= internal pull-down 5 k
Ω
on DSP bus master;
pu_m
= internal pull-up 5 k
Ω
on DSP bus master;
pu_ad
= internal pull-up 40 k
Ω
;
pd_l
= internal pull-down 50 k
Ω
. For more pull-down and pull-up information, see
Electrical Characteristics on
Page 22
.
Term (termination of unused pins) column symbols:
epd = external pull-down approximately 5 k
Ω
to V
SS
; epu = external pull-up approx-
imately 5 k
Ω
to V
DD_IO
, nc = not connected; na = not applicable (always used); V
DD_IO
= connect directly to V
DD_IO
; V
SS
= connect directly to V
SS
Table 12. Pin Definitions—Impedance Control, Drive Strength Control, and Regulator Enable
Signal
Type
Term
Description
CONTROLIMP0
CONTROLIMP1
I (pd)
I (pu)
na
na
Impedance Control. As shown in
Table 13
, the CONTROLIMP1–0 pins select between
normal driver mode and A/D driver mode. When using normal mode (recommended),
the output drive strength is set relative to maximum drive strength according to
Table 14
. When using A/D mode, the resistance control operates in the analog mode,
where drive strength is continuously controlled to match a specific line impedance as
shown in
Table 14
.
DS2, 0
DS1
I (pu)
I (pd)
na
Digital Drive Strength Selection. Selected as shown in
Table 14
. For drive strength calcu-
lation, see
Output Drive Currents on Page 36
. The drive strength for some pins is preset,
not controlled by the DS2–0 pins. The pins that are always at drive strength 7 (100%)
include: CPA, DPA, TDO, EMU, and RST_OUT. The drive strength for the ACK pin is always
x2 drive strength 7 (100%).
ENEDREG
I (pu)
V
SS
Connect the ENEDREG pin to V
SS
. Connect the V
DD_DRAM
pins to a properly decoupled
DRAM power supply.
I
= input;
A
= asynchronous;
O
= output;
OD
= open-drain output;
T
= three-state;
P
= power supply;
G
= ground;
pd
= internal pull-down
5 k
Ω
;
pu
= internal pull-up 5 k
Ω
;
pd_0
= internal pull-down 5 k
Ω
on DSP ID = 0;
pu_0
= internal pull-up 5 k
Ω
on DSP ID = 0;
pu_od_0
= internal
pull-up 500
Ω
on DSP ID = 0;
pd_m
= internal pull-down 5 k
Ω
on DSP bus master;
pu_m
= internal pull-up 5 k
Ω
on DSP bus master;
pu_ad
= internal pull-up 40 k
Ω
. For more pull-down and pull-up information, see
Electrical Characteristics on Page 22
.
Term (termination of unused pins) column symbols:
epd = external pull-down approximately 5 k
Ω
to V
SS
; epu = external pull-up approx-
imately 5 k
Ω
to V
DD_IO
, nc = not connected; na = not applicable (always used); V
DD_IO
= connect directly to V
DD_IO
; V
SS
= connect directly to V
SS